z-logo
open-access-imgOpen Access
Analytical Approach to Estimate Feeder Accommodation Limits Based on Protection Criteria
Author(s) -
Harsha V. Padullaparti,
Pisitpol Chirapongsananurak,
Miguel E. Hernandez,
Surya Santoso
Publication year - 2016
Publication title -
ieee access
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.587
H-Index - 127
ISSN - 2169-3536
DOI - 10.1109/access.2016.2589545
Subject(s) - aerospace , bioengineering , communication, networking and broadcast technologies , components, circuits, devices and systems , computing and processing , engineered materials, dielectrics and plasmas , engineering profession , fields, waves and electromagnetics , general topics for engineers , geoscience , nuclear engineering , photonics and electrooptics , power, energy and industry applications , robotics and control systems , signal processing and analysis , transportation
Widespread deployment of large-scale photovoltaics (PVs) and energy storage systems (ESSs) in distribution networks necessitates the development of methods to assess their possible system impacts. One of the primary concerns related to the integration of these systems is short-circuit overcurrent protection problems. Present techniques use simulations of full and detailed distribution circuit models with a large number of scenarios to estimate the PV and ESS sizes a distribution feeder can accommodate without causing adverse impacts. As this process requires considerable time and effort, this paper develops a practical and simplified analytical approach to conservatively estimate a utility distribution feeder's accommodation limits without causing protection problems. Sympathetic tripping and relay insensitivity problems are considered in this paper under both symmetrical and unsymmetrical fault conditions. Using the analysis presented, the factors influencing these protection problems are determined to provide insights into relay settings. The feeder accommodation limits obtained using the proposed analytical approach are compared with those obtained using simulations of an actual detailed distribution circuit model. The findings show that the proposed approach is accurate in estimating the feeder's accommodation limits for integrating large-scale PV and ESS.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom