z-logo
open-access-imgOpen Access
Oriented suspension mechanics with application to improving flow linear dichroism spectroscopy
Author(s) -
G. Cupples,
David J. Smith,
Matthew R. Hicks,
Rosemary Dyson
Publication year - 2019
Publication title -
proceedings of the royal society a mathematical physical and engineering sciences
Language(s) - English
Resource type - Journals
eISSN - 1471-2946
pISSN - 1364-5021
DOI - 10.1098/rspa.2019.0184
Subject(s) - linear dichroism , flow (mathematics) , dichroism , signal (programming language) , anisotropy , suspension (topology) , brownian dynamics , channel (broadcasting) , shear flow , materials science , perpendicular , circular dichroism , physics , mechanics , brownian motion , optics , chemistry , geometry , mathematics , crystallography , telecommunications , computer science , quantum mechanics , programming language , homotopy , pure mathematics
Flow linear dichroism is a biophysical spectroscopic technique that exploits the shear-induced alignment of elongated particles in suspension. Motivated by the broad aim of optimizing the sensitivity of this technique, and more specifically by a hand-held synthetic biotechnology prototype for waterborne-pathogen detection, a model of steady and oscillating pressure-driven channel flow and orientation dynamics of a suspension of slender microscopic fibres is developed. The model couples the Fokker–Planck equation for Brownian suspensions with the narrow channel flow equations, the latter modified to incorporate mechanical anisotropy induced by the particles. The linear dichroism signal is estimated through integrating the perpendicular components of the distribution function via an appropriate formula which takes the biaxial nature of the orientation into account. For the specific application of pathogen detection via binding of M13 bacteriophage, it is found that increases in the channel depth are more significant in improving the linear dichroism signal than increases in the channel width. Increasing the channel depth to 2 mm and pressure gradient to 5 × 10 4  Pa m −1 essentially maximizes the alignment. Oscillating flow can produce nearly equal alignment to steady flow at appropriate frequencies, which has significant potential practical value in the analysis of small sample volumes.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom