z-logo
open-access-imgOpen Access
The attenuated spline reconstruction technique for single photon emission computed tomography
Author(s) -
Nicholas Ε. Protonotarios,
A. S. Fokas,
Kostas Kostarelos,
George A. Kastis
Publication year - 2018
Publication title -
journal of the royal society interface
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.655
H-Index - 139
eISSN - 1742-5689
pISSN - 1742-5662
DOI - 10.1098/rsif.2018.0509
Subject(s) - imaging phantom , single photon emission computed tomography , iterative reconstruction , attenuation , computer vision , emission computed tomography , computer science , interpolation (computer graphics) , artificial intelligence , noise (video) , algorithm , physics , mathematics , positron emission tomography , optics , nuclear medicine , image (mathematics) , medicine
We present the attenuated spline reconstruction technique (aSRT) which provides an innovative algorithm for single photon emission computed tomography (SPECT) image reconstruction. aSRT is based on an analytic formula of the inverse attenuated Radon transform. It involves the computation of the Hilbert transforms of the linear attenuation function and of two sinusoidal functions of the so-called attenuated sinogram These computations are achieved by employing the attenuation information provided by computed tomography (CT) scans and by utilizing custom-made cubic spline interpolation. The purpose of this work is: (i) to present the mathematics of aSRT, (ii) to reconstruct simulated and real SPECT/CT data using aSRT and (iii) to evaluate aSRT by comparing it to filtered backprojection (FBP) and to ordered subsets expectation minimization (OSEM) reconstruction algorithms. Simulation studies were performed by using an image quality phantom and an appropriate attenuation map. Reconstructed images were generated for 45, 90 and 180 views over 360 degrees with 20 realizations and involved Poisson noise of three different levels (NL), namely 100% (NL1), 50% (NL2) and 10% (NL3) of the total counts, respectively. Moreover, real attenuated SPECT sinograms were reconstructed from a real study of a Jaszczak phantom, as well as from a real clinical myocardial SPECT/CT study. Comparisons between aSRT, FBP and OSEM reconstructions were performed using contrast, bias and image roughness. The results suggest that aSRT can efficiently produce accurate attenuation-corrected reconstructions for simulated and real phantoms, as well as for clinical data. In particular, in the case of the clinical myocardial study, aSRT produced reconstructions with higher cold contrast than both FBP and OSEM. aSRT, by incorporating the attenuation correction within itself, may provide an improved alternative to FBP. This is particularly promising for 'cold' regions as those occurring in myocardial ischaemia.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom