Impact of Subxiphoid Video Pericardioscopy with a Rigid Shaft on Cardiac Hemodynamics in a Porcine Model
Author(s) -
Yokota Takenori,
Ota Takeyoshi,
Schwartzman David,
Zenati Marco A.
Publication year - 2010
Publication title -
innovations: technology and techniques in cardiothoracic and vascular surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.467
H-Index - 24
eISSN - 1559-0879
pISSN - 1556-9845
DOI - 10.1097/imi.0b013e3181ceef8a
Subject(s) - hemodynamics , medicine , cardiology , central venous pressure , inferior vena cava , pericardium , sinus rhythm , ascending aorta , atrial fibrillation , azygos vein , superior vena cava , aorta , heart rate , anesthesia , blood pressure , anatomy
Objective Single-port subxiphoid videopericardioscopy with a rigid shaft is useful for left atrial exclusion, left ventricular (LV) pacing lead implantation, and epicardial mapping, but it may interfere with the cardiac rhythm and adversely alter hemodynamics. We examined the impact of this technique on hemodynamic indices in a porcine model.Methods The videopericardioscopy device was introduced into the pericardial space of five pigs (35–45 kg) via a subxiphoid approach and navigated to six anatomic targets [right atrial appendage, superior vena cava, ascending aorta, left atrial appendage (anterior and posterior approaches), transverse sinus, and atrioventricular (AV) groove]. After successful target acquisition, the device was withdrawn through the subxiphoid port. When the hemodynamics stabilized, the device was navigated to another target. The heart rate (HR), arterial blood pressure (BP), central venous pressure (CVP), pulmonary arterial pressure, and mixed venous oxygen saturation (SvO 2 ) were measured at every pretarget (subxiphoid incision) and target point. After the navigation trials, the animals were killed and the mediastinum space was examined for procedure-related injuries.Results The device afforded a good view, and the navigation trials were successfully performed on the beating heart. Four animals tolerated the procedures, whereas one died of device-induced ventricular fibrillation after the trials. Hemodynamics was severely compromised at all anatomic targets except the left atrial appendage (anterior approach).Conclusions Subxiphoid videopericardioscopy significantly interferes with the cardiac rhythm, causing life-threatening arrhythmia and hemodynamic compromise, when the target is located deep and far from the pericardiotomy. A flexible or highly articulated device would enable intrapericardial navigation without hemodynamic compromise.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom