z-logo
open-access-imgOpen Access
Interexaminer Agreement and Reliability of an Internationally Endorsed Screening Framework for Cervical Vascular Risks Following Manual Therapy and Exercise: The Go4Safe Project
Author(s) -
Rogier F de Best,
Michel W. Coppieters,
Emie van Trijffel,
Annette Compter,
Maarten Uyttenboogaart,
Joost Bot,
René Castien,
Jan Pool,
Barbara Cagnie,
G.G.M. Scholten-Peeters
Publication year - 2021
Publication title -
physical therapy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.998
H-Index - 150
eISSN - 1538-6724
pISSN - 0031-9023
DOI - 10.1093/ptj/pzab166
Subject(s) - reliability (semiconductor) , physical therapy , medicine , agreement , physical medicine and rehabilitation , linguistics , philosophy , power (physics) , physics , quantum mechanics
Objective Clinicians are recommended to use the clinical reasoning framework developed by the International Federation of Orthopaedic Manipulative Physical Therapists (IFOMPT) to provide guidance regarding assessment of the cervical spine and potential for cervical artery dysfunction prior to manual therapy and exercise. However, the interexaminer agreement and reliability of this framework is unknown. This study aimed to estimate the interexaminer agreement and reliability of the IFOMPT framework among physical therapists in primary care. Methods Ninety-six patients who consulted a physical therapist for neck pain or headache were included in the study. Each patient was tested independently by 2 physical therapists, from a group of 17 physical therapists (10 pairs) across The Netherlands. Patients and examiners were blinded to the test results. The overall interexaminer agreement, specific agreement per risk category (high-, intermediate-, and low-risk), and interexaminer reliability (weighted κ) were calculated. Results Overall agreement was 71% (specific agreement in high-risk category = 63%; specific agreement in intermediate-risk category = 38%; specific agreement in low-risk category = 84%). Overall reliability was moderate (weighted κ = 0.39; 95% CI = 0.21–0.57) and varied considerably between pairs of physical therapists (κ = 0.14–1.00). Conclusion The IFOMPT framework showed an insufficient interexaminer agreement and fair interexaminer reliability among physical therapists when screening the increased risks for vascular complications following manual therapy and exercise prior to treatment. Impact The IFOMPT framework contributes to the safety of manual therapy and exercise. It is widely adopted in clinical practice and educational programs, but the measurement properties are unknown. This project describes the agreement and reliability of the IFOMPT framework.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom