Hard X-Ray Detector (HXD) on Board Suzaku
Author(s) -
Tadayuki Takahashi,
Keiichi Abe,
Manabu Endo,
Yasuhiko Endo,
Y. Ezoe,
Yasushi Fukazawa,
M. Hamaya,
Shinya Hirakuri,
S. Hong,
Michihiro Horii,
Hokuto Inoue,
Naoki Isobe,
Takeshi Itoh,
Naoko Iyomoto,
T. Kamae,
Daisuke Kasama,
J. Kataoka,
Hiroshi Kato,
Madoka Kawaharada,
Naomi Kawano,
Keigo Kawashima,
S. Kawasoe,
T. Kishishita,
Takao Kitaguchi,
Y. Kobayashi,
M. Kokubun,
J. Kotoku,
M. Kouda,
Aya Kubota,
Yoshikatsu Kuroda,
G. M. Madejski,
Kazuo Makishima,
Kazunori Masukawa,
Y Matsumoto,
Takefumi Mitani,
Ryohei Miyawaki,
Tsunefumi Mizuno,
Kunishiro Mori,
Masanori Mori,
M. Murashima,
Toshio Murakami,
Kazuhiro Nakazawa,
Chiharu Sako,
Masaharu Nomachi,
Y. Okada,
M. Ohno,
Kousuke Oonuki,
Naomi Ota,
Hideki Ozawa,
Goro Sato,
S. Shinoda,
Masahiko Sugiho,
Masaya Suzuki,
Koji Taguchi,
H. Takahashi,
Isao Takahashi,
Shin׳ichiro Takeda,
Kenichi Tamura,
Takayuki Tamura,
Takaaki Tanaka,
C. Tanihata,
M. Tashiro,
Y. Terada,
Shinya Tominaga,
Y. Uchiyama,
Shin Watanabe,
K. Yamaoka,
Takayuki Yanagida,
Daisuke Yonetoku
Publication year - 2007
Publication title -
publications of the astronomical society of japan
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.99
H-Index - 110
eISSN - 2053-051X
pISSN - 0004-6264
DOI - 10.1093/pasj/59.sp1.s35
Subject(s) - physics , scintillator , detector , electromagnetic shielding , x ray detector , on board , diode , gamma ray , angular resolution (graph drawing) , pin diode , optics , astrophysics , optoelectronics , remote sensing , combinatorics , mathematics , quantum mechanics , geology
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom