z-logo
open-access-imgOpen Access
Phase-Reference VLBI Observations of the Compact Steep-Spectrum Source 3C 138
Author(s) -
Zhi-Qiang Shen,
L.L. Shang,
Dongrong Jiang,
Hongbing Cai,
Xi Chen
Publication year - 2006
Publication title -
publications of the astronomical society of japan
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.99
H-Index - 110
eISSN - 2053-051X
pISSN - 0004-6264
DOI - 10.1093/pasj/58.6.1033
Subject(s) - physics , very long baseline interferometry , right ascension , prime (order theory) , astrophysics , phase (matter) , quasar , position (finance) , declination , combinatorics , quantum mechanics , galaxy , mathematics , finance , economics
We investigate a phase-reference VLBI observation that was conducted at 15.4 GHz by fast switching VLBA antennas between the compact steep-spectrum radio source 3C 138 and the quasar PKS 0528+134 which are about 4$^\circ$ away on the sky. By comparing the phase-reference mapping with the conventional hybrid mapping, we demonstrate the feasibility of high precision astrometric measurements for sources separated by 4$^\circ$. VLBI phase-reference mapping preserves the relative phase information, and thus provides an accurate relative position between 3C 138 and PKS 0528+134 of $\Delta\alpha=-9^m46^s.531000\pm0^s.3$ and $\Delta\delta=3^\circ6^\prime26^{\prime\prime}.90311\pm0^{\prime\prime}.00007$ (J2000.0) in right ascension and declination, respectively. This gives an improved position of the nucleus (component A) of 3C 138 in J2000.0 to be RA=$05^h 21^m 9^s.885748$ and Dec=$16^\circ 38' 22''.05261$ under the assumption that the position of calibrator PKS 0528+134 is correct. We further made a hybrid map by performing several iterations of CLEAN and self-calibration on the phase-referenced data with the phase-reference map as an input model for the first phase self-calibration. Compared with the hybrid map from the limited visibility data directly obtained from fringe fitting 3C 138 data, this map has a similar dynamic range, but a higher angular resolution. Therefore, phase-reference technique is not only a means of phase connection, but also a means of increasing phase coherence time allowing self-calibration technique to be applied to much weaker sources

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom