z-logo
open-access-imgOpen Access
Clinical Validation of a Commercial LAMP Test for Ruling out Malaria in Returning Travelers: A Prospective Diagnostic Trial
Author(s) -
James Cheaveau,
Hong Nguyen,
Barbara L. Chow,
Dewdunee Marasinghe,
Abu Naser Mohon,
Hongbin Yuan,
Gisele M. R. Viana,
Donelly A. van Schalkwyk,
Deirdre L. Church,
Wilson Chan,
Dylan R. Pillai
Publication year - 2018
Publication title -
open forum infectious diseases
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.546
H-Index - 35
ISSN - 2328-8957
DOI - 10.1093/ofid/ofy260
Subject(s) - medicine , malaria , test (biology) , clinical trial , medical physics , diagnostic test , family medicine , optometry , pediatrics , pathology , paleontology , biology
The mainstay of malaria diagnosis relies on rapid diagnostic tests (RDTs) and microscopy, both of which lack analytical sensitivity. This leads to repeat testing to rule out malaria. A prospective diagnostic trial of the Meridian Malaria assay (loop-mediated isothermal amplification [LAMP]) was conducted comparing it with reference microscopy and RDTs (BinaxNOW Malaria) in returning travelers between June 2017 and January 2018. Returning travelers with signs and symptoms of malaria were enrolled in the study. RDTs, microscopy, and LAMP assays were performed simultaneously. A total of 298 patients (50.7% male; mean age, 32.5 years) were enrolled, most visiting friends and relatives (43.3%), presenting with fever (88.9%), not taking prophylaxis (82.9%), and treated as outpatients (84.1%). In the prospective arm (n = 348), LAMP had a sensitivity of 98.1% (95% confidence interval [CI], 90.0%-100%) and a specificity of 97.6% (95% CI, 95.2%-99.1%) vs microscopy. After discrepant resolution with real-time polymerase chain reaction, LAMP had a sensitivity of 100% (95% CI, 93.7%-100%) and a specificity of 100% (95% CI, 98.7%-100%) vs microscopy. After discrepant resolution, RDTs had a sensitivity of 83.3% (95% CI, 58.6%-96.4%) and a specificity of 96.2% (95% CI, 93.2%-98.1%) vs microscopy. When including retrospective specimens (n = 377), LAMP had a sensitivity of 98.8% (95% CI, 93.2%-100%) and a specificity of 97.6% (95% CI, 95.2%-99.1%) vs microscopy, and after discrepant resolution of this set, LAMP had a sensitivity of 100% (95% CI, 95.8%-100%) and a specificity of 100% (95% CI, 98.7%-100%). A cost-benefit analysis of reagents and labor suggests savings of up to USD$13 per specimen using a novel algorithm with LAMP screening.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom