674. Evaluation of the Access Bio CareStart™ Rapid SARS-CoV-2 Antigen Test in Asymptomatic Individuals Tested at a Community Mass-testing Program in Western Massachusetts
Author(s) -
Wilfredo R. Matias,
Sara Suliman,
Isabel Fulcher,
Francisco Molano,
Shan Collins,
Elizabeth Uceta,
Jack Zhu,
Ryan Paxton,
Sean F. Gonsalves,
Maegan Harden,
Marissa Fisher,
Jim Meldrim,
Stacey Gabriel,
Molly F. Franke,
Deborah T. Hung,
Sandra Smole,
Lawrence C. Madoff,
Louise C. Ivers
Publication year - 2021
Publication title -
open forum infectious diseases
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.546
H-Index - 35
ISSN - 2328-8957
DOI - 10.1093/ofid/ofab466.871
Subject(s) - medicine , gold standard (test) , asymptomatic , antigen , real time polymerase chain reaction , population , immunology , virology , gene , biology , biochemistry , environmental health
Background Point-of-care antigen-detecting rapid diagnostic tests (RDTs) to detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) represent a scalable tool for surveillance of active SARS-CoV-2 infections in the population. Data on the performance of these tests in real-world community settings will be paramount for their implementation to combat the COVID-19 pandemic. Methods We evaluated the performance characteristics of the CareStartTM COVID-19 Antigen Test (CareStart) in a community testing site in Holyoke, Massachusetts. We compared CareStart to a SARS-CoV-2 reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) reference, both using anterior nasal swab samples. We calculated the sensitivity, specificity, and the expected positive and negative predictive values at different SARS-CoV-2 prevalence estimates. Results We performed 666 total tests on 591 unique individuals. 573 (86%) were asymptomatic. There were 52 positive tests by RT-qPCR. The sensitivity of CareStart was 49.0% (95% Confidence Interval (CI): 34.8 – 63.4) and specificity was 99.5% (95% CI: 98.5 – 99.9). Among positive RT-qPCR tests, the median cycle threshold (Ct) was significantly lower in samples that tested positive on CareStart. Using a Ct less than or equal to 30 as a benchmark for positivity increased the sensitivity of the test to 64.9% (95% CI: 47.5 – 79.8). Performance characteristics of CareStart test results benchmarked against the RT-qPCR gold standard (excluding undetermined results). Examples of images of CareStart rapid test showing variable band intensities. N2 gene RT-qPCR Cycle threshold (Ct) values corresponding to positive and negative CareStart rapid antigen test results for all RT-qPCR positive samples (n=52). Conclusion Our study shows that CareStart has a high specificity and moderate sensitivity. The utility of RDTs, such as CareStart, in mass implementation should prioritize use cases in which a higher specificity is more important, such as triage tests to rule-in active infections in community surveillance programs. Disclosures All Authors: No reported disclosures