z-logo
open-access-imgOpen Access
The ultrafiltration coefficient: this old 'grand inconnu' in dialysis
Author(s) -
Alain Ficheux,
Claudio Ronco,
Philippe Brunet,
Àngel Argilés
Publication year - 2013
Publication title -
nephrology dialysis transplantation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.654
H-Index - 168
eISSN - 1460-2385
pISSN - 0931-0509
DOI - 10.1093/ndt/gft493
Subject(s) - membrane , ultrafiltration (renal) , dialysis , polymer science , chemistry , dialysis tubing , chromatography , medicine , surgery , biochemistry
Although a wide range of physical principles capable of separating different solutes exist in biochemistry (such as affinity, or size as well as charge retaining columns and others), the removal of uraemic solutes has been almost exclusively performed up to the present with membrane-based systems. Sir Thomas Graham, in the second half of the 1800s, defined the method of separating various fluids by diffusion through a membrane with the term ‘dialysis’[1]. Galen in the second century of our era already claimed that the skin resembles a sieve and ‘sweating purifies the body, … by low-effort exercise, baths and the summer heat’ [De Symptomatum Causis Libri III, Claudii Galeni Opera Omnia (II)][2], and ancient Romans used the skin as a natural membrane to rid their bodies of poisonous urinal substances in the Therms and public baths. Well into the 20th century, artificial kidneys, based on membrane devices were adopted and the pioneer work by Abel, Rowntree and Turner [3], as well as that of Haas [4], was followed by the rotatory drum dialyser of Willem Kolff [5] and the vertical drum one of Nils Alwall [6]. Finally, the hollow fibre dialysers gained adepts and a widespread use of cuprophane membranes for a very long period of time (from the 1970s to the 1990s) has been followed by the introduction of high-flux membranes that have invaded most of the dialysis units worldwide to the present. It became quite clear from the very beginning that membranes differ in their clearance capacities of the different solutes, basically depending on thickness and pore size. However, increasing the pore size and reducing thickness is almost forcedly associated to a water permeability increase. The open dialysate circuit settings used during the era of low-permeability membranes had to be secured by the addition of ultrafiltration controllers, which closed the dialysis circuit [7], and are mandatory when using high-flux membranes (highly permeable to water) particularly if convective techniques are utilized. Defining water permeability of a dialyser was considered important from the beginning and is even more important with the high-flux dialysers. Water permeability of a dialyser was defined by its ultrafiltration coefficient, which is displayed in the notice of the given dialyser. The coefficient of ultrafiltration (KUF) was first defined by the amount of fluid (V) in mL crossing the dialyser membrane per time (T) in hours and pressure (P) in mmHg: KUF=VT×P

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom