Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure
Author(s) -
E. Wijnen,
R. Nils Planken,
Xavier H.A. Keuter,
J. P. Kooman,
Jan H.M. Tordoir,
Michiel W. de Haan,
Karel M.L. Leunissen,
Frank M. van der Sande
Publication year - 2006
Publication title -
nephrology dialysis transplantation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.654
H-Index - 168
eISSN - 1460-2385
pISSN - 0931-0509
DOI - 10.1093/ndt/gfl424
Subject(s) - medicine , vascular access , percutaneous , psychological intervention , hemodialysis , angioplasty , surgery , thrombosis , stenosis , catheter , emergency medicine , psychiatry
Vascular access thrombosis is a substantial source of morbidity in chronic haemodialysis patients. Periodical access flow measurements can predict the presence of vascular access stenosis and provide an opportunity for early intervention to prevent subsequent vascular access thrombosis. By this system of quality improvement, vascular access-related costs might be reduced. The aim of this study was to analyse the cost impact of a quality improvement programme based on periodic access flow measurements.