Quantification of the temperature equilibrium time of the cavity in parallel-plate-type ionization chambers by thermal analysis
Author(s) -
Hiraku Fuse,
Soma Hirota,
Tatsuya Fujisaki,
Shinji Abe,
Kenji Yasue,
Koichi Hanada,
Fumihiro Tomita
Publication year - 2021
Publication title -
journal of radiation research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.643
H-Index - 60
eISSN - 1349-9157
pISSN - 0449-3060
DOI - 10.1093/jrr/rrab073
Subject(s) - ionization chamber , ionization , thermal equilibrium , thermal ionization , dosimetry , materials science , atomic physics , thermal , dosimeter , analytical chemistry (journal) , chemistry , physics , radiation , optics , ion , nuclear medicine , electron ionization , thermodynamics , medicine , organic chemistry , chromatography
Temperature corrections are necessary to account for the varying mass of air in the cavity volume of a vented ionization chamber. The temporal response resulting from temperature changes in a cylindrical and/or Farmer-type ionization chamber, which is the standard dosimeter, has been thoroughly discussed by some researchers. The purpose of this study was to characterise and analyse the dependence of the cavity air temperature of the parallel-plate-type ionization chamber on changes in the ambient temperature. Ionization chambers NACP-02 (IBA Dosimetry, GmbH) and Advanced Markus TN34045 (PTW, Freiburg) were modelled using thermal analysis software to present the temperature equilibrium time and the entire ionization chamber temperature distribution. The temporal response of each ionization chamber was measured for comparing the calculation results of the thermal analysis. The ionization chamber cavities of NACP-02 and TN34045 reached complete equilibrium in 670 and 750 s, respectively. Heat transfer occurred faster at the centre of the front wall of TN34045 than at the outside of the centre except for the edges. Further, the non-uniformity of temperature in the cavity was in the range of 24.2-24.8°C for NACP-02 and 23.7-24.4°C for TN34045 at 200 s after the ionization chamber was installed in the water phantom. The previous proposal to wait for about 15 mins after submerging the chamber in a water phantom before the measurement is demonstrated to be appropriate for parallel-plate-type ionization chambers.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom