Determination of ∆-9-Tetrahydrocannabinol (THC), 11-hydroxy-THC, 11-nor-9-carboxy-THC and Cannabidiol in Human Plasma using Gas Chromatography–Tandem Mass Spectrometry
Author(s) -
David M. Andrenyak,
David E. Moody,
Matthew H. Slawson,
Daniel S. OʼLeary,
Margaret Haney
Publication year - 2016
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/bkw136
Subject(s) - cannabidiol , chemistry , chromatography , tetrahydrocannabinol , human plasma , cannabinol , cannabinoid , δ9 tetrahydrocannabinol , tandem mass spectrometry , mass spectrometry , dronabinol , gas chromatography–mass spectrometry , gas chromatography , cannabis , biochemistry , medicine , receptor , psychiatry
Two marijuana compounds of particular medical interest are delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD). A gas chromatography-tandem mass spectrometry (GC-MS-MS) method was developed to test for CBD, THC, hydroxy-THC (OH-THC) and carboxy-THC (COOH-THC) in human plasma. Calibrators (THC and OH-THC, 0.1 to 100; CBD, 0.25 to 100; COOH-THC, 0.5-500 ng/mL) and controls (0.3, 5 and 80 ng/mL, except COOH-THC at 1.5, 25 and 400 ng/mL) were prepared in blank matrix. Deuterated (d3) internal standards were added to 1-mL samples. Preparation involved acetonitrile precipitation, liquid-liquid extraction (hexane:ethyl acetate, 9:1), and MSTFA derivatization. An Agilent 7890 A GC was interfaced with an Agilent 7000 MS Triple Quadrupole. Selected reaction monitoring was employed. Blood samples were provided from a marijuana smoking study (two participants) and a CBD ingestion study (eight participants). Three analytes with the same transitions (THC, OH-THC and COOH-THC) were chromatographically separated. Matrix selectivity studies showed endogenous chromatographic peak area ratios (PAR) at the analyte retention times were <20% of the analyte limit of quantitation PAR. The intra-assay accuracy ranged from 83.5% to 118% of target and the intra-run imprecision ranged from 2.0% to 19.1%. The inter-assay accuracy ranged from 90.3% to 104% of target and the inter-run imprecision ranged from 6.5% to 12.0%. Stability was established for 25 hours at room temperature, 207 days at -20°C, after three freeze-thaw cycles and for 26 days for rederivatized processed samples. After smoking marijuana predictable concentrations of THC, OH-THC and COOH-THC were seen; low concentrations of CBD were detected at early time points. In moderate users who had not smoked for at least 9 hours before ingesting an 800 mg oral dose of CBD, the method was sensitive enough to follow residual concentrations of THC and OH-THC; sustained COOH-THC concentrations over 50 ng/mL validated its higher analytical range.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom