z-logo
open-access-imgOpen Access
Evaluation of a Newly Formulated Enzyme Immunoassay for the Detection of Hydrocodone and Hydromorphone in Pain Management Compliance Testing
Author(s) -
Renata Ramos Nascimento,
Alphonse Poklis,
Carl E. Wolf
Publication year - 2016
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/bkw080
Subject(s) - hydromorphone , hydrocodone , chromatography , immunoassay , chemistry , urine , mass spectrometry , cutoff , high performance liquid chromatography , detection limit , medicine , opioid , biochemistry , oxycodone , receptor , physics , quantum mechanics , antibody , immunology
A new Hydrocodone Enzyme Immunoassay (HEIA; Lin-Zhi International, Inc.) was evaluated for the detection of hydrocodone and its main metabolite, hydromorphone. All specimens were tested with two different cutoff calibrators, 100 and 300 ng/mL, on an ARCHITECT Plus c4000 Clinical Chemistry Analyzer. Controls containing -25% (negative control) and +25% (positive control) of the cutoff calibrators and a drug-free control were analyzed with each batch. All 1,025 urine specimens were previously analyzed by ultra-performance liquid chromatography-mass spectrometry/mass spectrometry (UPLC-MS-MS) for opiates. Approximately, 33% (337/1,019) of the specimens yielded positive results by the HEIA assay at a cutoff concentration of 100 ng/mL and 19% (190/1,025) yielded positive results at the 300 ng/mL cutoff concentration. Of these presumptive positive specimens, UPLC-MS-MS confirmed the presence of hydrocodone and/or hydromorphone >100 ng/mL in 241 specimens and >300 ng/mL in 162 specimens, for each respective cutoff. With the 100 ng/mL cutoff, the HEIA demonstrated a sensitivity of 0.959, a specificity of 0.846 and an overall agreement with the UPLC-MS-MS of 87%. At 300 ng/mL cutoff, the HEIA demonstrated a sensitivity of 0.880, a specificity of 0.966 and an overall agreement of UPLC-MS-MS results of 95%. The Lin-Zhi HEIA 100 ng/mL cutoff assay demonstrated sensitivity for the detection of hydrocodone and hydromorphone in urine. The 300 ng/mL cutoff was less sensitive, but more selective, and should be part of an initial immunoassay screen, particularly in pain management compliance testing.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom