Comparison of an Automated and Point-of-Care Immunoassay to GC-MS for Urine Oxycodone Testing in the Clinical Laboratory
Author(s) -
Christine Haller,
Judith Stone,
V. Burke,
Jonathan R. Branch,
Ke Chen,
Susan J. Gross
Publication year - 2006
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/30.2.106
Subject(s) - immunoassay , urine , oxycodone , chromatography , point of care testing , gas chromatography–mass spectrometry , point of care , medicine , pharmacology , chemistry , mass spectrometry , pathology , immunology , opioid , receptor , antibody
OxyContin, a controlled-release formulation of oxycodone, is increasingly abused. Monitoring patient compliance by urine drug testing may deter illegal diversion of OxyContin. Two urine immunoassays were evaluated with a 100 ng/mL cutoff for oxycodone. The Microgenics Corporation Oxycodone DRI on the Bayer ADVIA 1650 and a point-of-care (POC) immunoassay, Monitect Oxycodone POC from Branan Medical Corporation, were compared to gas chromatography-mass spectrometry (GC-MS) with a detection limit of 50 ng/mL free oxycodone. Between-day precision for DRI yielded coefficients of variation from 3.9% to 7.0% at 75 and 125 ng/mL. Fifty-two positive and 52 negative urines were tested. The DRI had a 100% agreement with GC-MS. Two positive specimens had free oxycodone < 50 ng/mL, but oxycodone metabolites, oxymorphone and oxycodone glucuronide > 100 ng/mL, were identified by GC-MS analysis. The POC assay had two false positives and 15 indeterminate (+/-) results. Codeine or hydrocodone was present in all but one of these samples. There was no interference with DRI from morphine, codeine, hydrocodone, hydromorphone, dihydrocodeine, or 6-monoacetyl morphine. Four-hundred and ninety urine samples were subsequently tested with DRI to estimate the oxycodone-positive rate at our hospital, and 47 (9.4%) were positive. The confirmation rate with GC-MS for free oxycodone, not including metabolites, was 93%. The Microgenics DRI offers good performance for oxycodone urine testing and is a better choice for the clinical laboratory than the POC assay. Confirmation of screened positive samples requires a method that can detect total oxycodone and oxymorphone.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom