z-logo
open-access-imgOpen Access
Sevoflurane Analysis in Serum by Headspace Gas Chromatography with Application to Various Biological Matrices
Author(s) -
David Burrows,
Athanassios Nicolaides,
Grover C. Stephens,
Kenneth E. Ferslew
Publication year - 2004
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/28.6.418
Subject(s) - sevoflurane , chromatography , chemistry , gas chromatography , flame ionization detector , correlation coefficient , analytical chemistry (journal) , anesthesia , medicine , statistics , mathematics
Sevoflurane is a nonflammable general anesthetic administered by inhalation of vaporized liquid that rapidly partitions out of aqueous biological matrices into a gaseous phase because of its volatility and hydrophobicity. We describe a headspace analysis of sevoflurane that can be performed without the use of an expensive automated headspace analyzer. Sevoflurane standards (0-109 mg/L) and quality control specimens (12.2 and 72.9 mg/L) were prepared and quantitated on an intraday and interday basis. Headspace gas was manually injected (150 degrees C) with a 2.5-mL gas-tight syringe into a Perkin-Elmer model 8500 gas chromatograph equipped with a 6-ft x 2-mm i.d. glass column (100 degrees C) containing 0.2% Carbowax 1500 on Carbopak C packing with a flame-ionization detector (200 degrees C), which allowed for elution of the internal standard, 1-propanol (1.56 min), and sevoflurane (2.92 min). Linear regression of the peak-area ratios of sevoflurane to 1-propanol (6.38 g/L), versus the sevoflurane concentrations yielded an average intraday correlation coefficient of 0.989 (S.D. = 0.003, n = 5) and mean quality control specimen values of 14.19 mg/L (C.V. = 5.1%, n = 5) and 66.72 mg/L (C.V. = 3.3%, n = 5). The average interday standard curve correlation coefficient was 0.987 (S.D. = 0.01, n = 5), and the mean quality control specimen values were 12.22 mg/L (C.V. = 13.7%, n = 5) and 74.27 mg/L (C.V. = 8.7%, n = 5). The chromatographic method described produced accurate and reproducible results with a simple on-column headspace gas injection. This method allows for quantitation of sevoflurane in various biological matrices by chromatographic separation of the headspace gas in a sealed specimen container.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom