Flunitrazepam Excretion Patterns using the Abuscreen OnTrak and OnLine Immunoassays: Comparison with GC-MS
Author(s) -
Salvatore J. Salamone,
S. Honasoge,
Carla G. B. Brenner,
A. J. McNally,
J Passarelli,
K. Goc-Szkutnicka,
Rudolf Brenneisen,
Mahmoud A. ElSohly,
Shixia Feng
Publication year - 1997
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/21.5.341
Subject(s) - urine , desmethyl , chromatography , chemistry , gas chromatography–mass spectrometry , immunoassay , mass spectrometry , medicine , biochemistry , metabolite , antibody , immunology
A study was conducted to compare the performance of the OnLine and OnTrak immunoassays for benzodiazepines with gas chromatographic-mass spectrometric (GC-MS) analysis in detecting flunitrazepam (FNP) and its metabolites in human urine. Urine was collected over a 72-h period from six individuals (four male and two female) who had taken a single oral dose of either 1 or 4 mg of FNP. The OnTrak assay was run at a 100-ng/mL cutoff of nordiazepam (NDP), and the OnLine assay was run with a standard curve from zero to 200 ng/mL of NDP with and without beta-glucuronidase treatment. Each sample was analyzed by GC-MS using FNP, 7-amino-FNP, 3-hydroxy-FNP, desmethyl-FNP, 7-amino-3-hydroxy-FNP, and desmethyl-3-hydroxy-FNP as standards with beta-glucuronidase treatment. The specimens from the 1-mg dose did not yield a positive result by immunoassay over the 72-h collection period. Specimens from the 4-mg dose did yield positive results in both immunoassays. The time of the first positive result ranged from 4 to 12 h, and the time to the last positive result ranged from 18 to 60 h. Treatment of the samples with beta-glucuronidase increased the OnLine values between 20 and 60%, but it did not appreciably increase the detection time. GC-MS analysis showed no detectable levels of FNP, 3-hydroxy-FNP, desmethyl-FNP, 7-amino-3-hydroxy-FNP, and desmethyl-3-hydroxy-FNP. However, all samples collected past time zero showed detectable levels of 7-amino-FNP (> 2 ng/mL) with peak concentrations at 12-36 h. The peak levels of 7-amino-FNP by GC-MS paralleled the peak levels of the immunoassay response. The amount of 7-amino-FNP metabolite quantitated by GC-MS, however, accounted for only 15-20% of the total immunoassay crossreactive FNP metabolites.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom