A Single-Column Gas Chromatography Method for Quantifying Toxic Alcohols
Author(s) -
David J. Kemble,
Mark A Cervinski
Publication year - 2020
Publication title -
the journal of applied laboratory medicine
Language(s) - English
Resource type - Journals
eISSN - 2576-9456
pISSN - 2475-7241
DOI - 10.1093/jalm/jfz019
Subject(s) - chromatography , ethylene glycol , gas chromatography , chemistry , alcohol , detection limit , flame ionization detector , sample preparation , ethanol , organic chemistry
Background Rapid identification and quantification of toxic alcohols and ethylene glycol is imperative for appropriate treatment. Clinical laboratories frequently rely on direct injection gas chromatography (GC) methods, but these methods require inlet maintenance and multiple GC systems. To overcome these challenges, we developed a single-column headspace GC method for both toxic alcohols and glycols that streamlines patient sample analysis for toxic alcohol ingestion. Methods Optimal parameters for nonderivatized (volatile) and derivatized (glycol) plasma samples were determined using a 7890 A headspace sampler, an Agilent 7697 A GC system, a DB-200 column, and a flame ionization detector. Limit of Quantification (LoQ), linearity, imprecision, carry-over, method comparison, and interference studies were performed using quality control materials and prepared plasma samples. Results Our volatile method is linear to 3000 mg/L (ethanol) with LoQ concentrations below 20 mg/L (ethanol). The glycol method is linear to 2000 mg/L (ethylene glycol) with LoQ concentrations below 40 mg/L (ethylene glycol). Total assay impression ranged from 1.7% for ethanol to 13.3% for propylene glycol. Both methods were free of sample carryover and compared favorably with a similar clinical method at an outside laboratory. Propionic acid, an accumulating metabolite in methylmalonic acidemia that interferes with ethylene glycol identification by a different method, did not interfere with the ethylene glycol method reported here. Conclusions Our single-column headspace GC method provides reliable, robust, and rapid identification and quantification of commonly encountered toxic alcohols. Clinical laboratories relying on direct injection Gas Chromatography (GC) for toxic alcohol analysis face challenges including frequent inlet maintenance, sample carryover, or the need for separate GC systems for volatile and glycol analysis. We summarize our development and optimization of two headspace GC methods for nonderivatized (volatile) and derivatized (glycol) plasma samples that use a single DB-200 analytical column. These methods are comparable to other GC methods, not prone to sample carryover, eliminate the need for multiple GC systems or columns, and are readily applicable to other laboratories that provide toxic alcohol analysis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom