AACC Guidance Document on Biotin Interference in Laboratory Tests
Author(s) -
Danni Li,
Angela M. Ferguson,
Mark A Cervinski,
Kara L. Lynch,
Patrick B. Kyle
Publication year - 2020
Publication title -
the journal of applied laboratory medicine
Language(s) - English
Resource type - Journals
eISSN - 2576-9456
pISSN - 2475-7241
DOI - 10.1093/jalm/jfz010
Subject(s) - biotin , biotinylation , streptavidin , in vivo , medicine , chemistry , biochemistry , biology , microbiology and biotechnology
Background Laboratory tests that use streptavidin–biotin binding mechanisms have the potential to be affected by high circulating biotin concentrations, which would produce positive and negative interference in biotinylated competitive and noncompetitive (sandwich) immunoassays, respectively. Consumption of high-dose biotin supplements for cosmetic or health-related reasons has drawn attention to biotin interference in clinical laboratory tests. Case reports and in vivo studies show that ingestion of supplemental biotin can cause clinically significant errors in select biotinylated immunoassays. Content This AACC Academy document is intended to provide guidance to laboratorians and clinicians for preventing, identifying, and dealing with biotin interference. In vivo and in vitro spiking studies have demonstrated that biotin concentrations required to cause interference vary by test and by manufacturer. This document includes discussion of biotin’s mechanisms for interference in immunoassays, pharmacokinetics, and results of in vitro and in vivo studies and cites examples of assays known to be affected by high biotin concentrations. This document also provides guidance recommendations intended to assist laboratories and clinicians in identifying and addressing biotin interference in laboratory testing. Summary The recent increase in the use of high-dose biotin supplements requires laboratorians and clinicians to be mindful of the potential for biotin interference in biotinylated immunoassay-based laboratory tests. Laboratories, clinicians, regulators, and patients should work together to ensure accurate laboratory results. Laboratories have several options for identifying suspected biotin interference in specimens. Alternatively, the relatively fast elimination of biotin allows the potential for rapid follow-up specimen analysis if necessary.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom