Tourniquet fixing prior to knot tying reduces forces during aortic valve replacement: experimental results from 18 surgeons
Author(s) -
Martin Hartrumpf,
Josephine Sterner,
Filip Schroeter,
Ralf-Uwe Kuehnel,
Magdalena Laux,
Christian Braun,
Johannes M. Albes
Publication year - 2020
Publication title -
interactive cardiovascular and thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.546
H-Index - 56
eISSN - 1569-9293
pISSN - 1569-9285
DOI - 10.1093/icvts/ivaa135
Subject(s) - medicine , tourniquet , surgery
OBJECTIVES To increase the safety of aortic valve replacement, we developed the ‘Caput medusae’ method, where the prosthesis is prefixed with circumferential tourniquets prior to knot tying. We assumed that an even distribution of forces may help reduce tissue damage. To confirm this theoretically, we compared forces between knots and tourniquets. METHODS The experimental set-up included a device with movable acrylic plates, a mounted valve and a set of sutures. Traction forces were measured with a luggage scale. Two different tourniquets were compared individually and as bundles of 15. Force–path curves were generated. Knotting and tourniquet forces of 18 staff surgeons were then compared. Both modalities were measured 10 times on 2 days, resulting in 40 observations per surgeon, or 360 observations per modality. RESULTS Polyvinyl chloride tourniquets were stiffer than silicone, expressed by a 1.5- to 1.7-fold higher regression-line slope. Fifteen simultaneous tubes produced force increments 7.9–8.9 times higher than their single counterparts. Overall knotting force was 13.64 ± 5.76 vs tourniquet 1.08 ± 0.48 N. Male surgeons’ knotting forces were higher compared to female staff (14.76 ± 6.01 vs 10.73 ± 3.74 N; P < 0.001) while tourniquet forces did not differ (1.09 ± 0.47 vs 1.05 ± 0.49 N; P = 0.459). Dedicated valve surgeons (n = 10) tightened the tourniquets more strongly than inexperienced surgeons (1.20 ± 0.52 vs 0.94 ± 0.37 N; P < 0.001); knotting was similar. Multivariable analysis confirmed only valve experience as a predictor of tourniquet strength (experienced surgeons exerted higher force). CONCLUSIONS Tourniquets exert less force on the tissue than knots. When distributed over the circumference, they can reduce local tension and avoid potential paravalvular leakage. Complete or partial use of tourniquets may thus be an additional option to enhance surgical safety.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom