Assessing Small Bowel Stricturing and Morphology in Crohn’s Disease Using Semi-automated Image Analysis
Author(s) -
Ryan W. Stidham,
Binu Enchakalody,
Akbar K. Waljee,
Peter Higgins,
Stewart C. Wang,
Grace L. Su,
Ashish P. Wasnik,
Mahmoud M. Al-Hawary
Publication year - 2019
Publication title -
inflammatory bowel diseases
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.932
H-Index - 146
eISSN - 1536-4844
pISSN - 1078-0998
DOI - 10.1093/ibd/izz196
Subject(s) - medicine , crohn's disease , inflammatory bowel disease , nuclear medicine , radiology , lumen (anatomy) , correlation , mathematics , disease , geometry
Background Evaluating structural damage using imaging is essential for the evaluation of small intestinal Crohn’s disease (CD), but it is limited by potential interobserver variation. We compared the agreement of enterography-based bowel damage measurements collected by experienced radiologists and a semi-automated image analysis system. Methods Patients with small bowel CD undergoing a CT-enterography (CTE) between 2011 and 2017 in a tertiary care setting were retrospectively reviewed. CT-enterography studies were reviewed by 2 experienced radiologists and separately underwent automated computer image analysis using bowel measurement software. Measurements included maximum bowel wall thickness (BWT-max), maximum bowel dilation (DIL-max), minimum lumen diameter (LUM-min), and the presence of a stricture. Measurement correlation coefficients and paired t tests were used to compare individual operator measurements. Multivariate regression was used to model identification of strictures using semi-automated measures. Results In 138 studies, the correlation between radiologists and semi-automated measures were similar for BWT-max (r = 0.724, 0.702), DIL-max (r = 0.812, 0.748), and LUM-min (r = 0.428, 0.381), respectively. Mean absolute measurement difference between semi-automated and radiologist measures were no different from the mean difference between paired radiologists for BWT-max (1.26 mm vs 1.12 mm, P = 0.857), DIL-max (2.78 mm vs 2.67 mm, P = 0.557), and LUM-min (0.54 mm vs 0.41 mm, P = 0.596). Finally, models of radiologist-defined intestinal strictures using automatically acquired measurements had an accuracy of 87.6%. Conclusion Structural bowel damage measurements collected by semi-automated approaches are comparable to those of experienced radiologists. Radiomic measures of CD will become an important new data source powering clinical decision-making, patient-phenotyping, and assisting radiologists in reporting objective measures of disease status.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom