Subject(s) - medicine , intensive care medicine , cardiac resynchronization therapy , implantable cardioverter defibrillator , perioperative , infection control , antibiotic prophylaxis , risk of infection , evidence based medicine , antibiotics , surgery , heart failure , ejection fraction , alternative medicine , microbiology and biotechnology , biology , pathology , genetics
A significant increase in the implantation of cardiac implantable electronic devices (CIEDs) is evident over the past years, while there is evidence for a disproportionate increase in CIED-related infections. The cumulative probability of device infection seems to be higher in implantable cardioverter defibrillator and in cardiac resynchronization therapy patients compared with permanent pacemaker patients. Given that more than a half of CIED infections are possibly related to the operative procedure, there is a need for effective periprocedural infection control. However, many of the current recommendations are empirical and not evidence-based, while questions, unresolved issues, and conflicting evidence arise. The perioperative systemic use of antibiotics confers significant benefit in prevention of CIED infections. However, there are no conclusive data regarding the specific value of each agent in different clinical settings, the value of post-operative antibiotic treatment as well as the optimal duration of therapy. The merit of local pocket irrigation with antibiotic and/or antiseptic agents remains unproved. Of note, recent evidence indicates that the application of antibacterial envelopes into the device pocket markedly decreases the infection risk. In addition, limited reports on strict integrated infection control protocols show a dramatic reduction in infection rates in this setting and therefore deserve further attention. Finally, the relative impact of particular factors on the infection risk, including the type of the CIED, patients' individual characteristics and comorbidities, should be further examined since it may facilitate the development of tailored prophylactic interventions for each patient.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom