z-logo
open-access-imgOpen Access
Immediate loading of orthodontic mini-implants: a histomorphometric evaluation of tissue reaction
Author(s) -
Cesare Luzi,
Carlalberta Verna,
B. Melsen
Publication year - 2009
Publication title -
european journal of orthodontics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.252
H-Index - 84
eISSN - 1460-2210
pISSN - 0141-5387
DOI - 10.1093/ejo/cjn087
Subject(s) - dentistry , implant , osseointegration , medicine , orthodontics , materials science , biomedical engineering , surgery
Although immediate loading of orthodontic mini-implants can be clinically successful, a lack of histological data exists. The present investigation was performed to evaluate, in an animal model, tissue reaction to immediate loading. Fifty orthodontic titanium mini-implants were inserted in four adult male monkeys at four time intervals. Forty-two devices were loaded with 50 cN super-elastic coil springs immediately after insertion while eight were left unloaded and served as the controls. After euthanasia, the following histomorphometric parameters were evaluated: bone volume (BV/TV), bone-to-implant contact (BIC), mineralizing surface (MS/BS), and erosion surface (ES/BS). Statistical analysis was performed by means of non-parametric tests. Four devices were removed because of loss of stability. A wide variation between animals was found for all parameters. BV/TV: slightly higher values were found in the unloaded sample. Although no particular trend was observed, at 3 months higher values were found in the lower jaw. BIC: a trend to a decrease between 1 week and 1 month followed by a significantly progressive increase was observed. Implants that showed some sections with as little as 3 per cent BIC successfully resisted loading. MS/BS: higher values were found in the lower jaw. MS/BS increased significantly between 1 week and 1 month, followed by a progressive decrease. ES/BS: there was a decrease between 1 week and 1 month, followed by a progressive re-increase. BV/TV did not show any particular trend while BIC was a time-dependent factor. MS/BS and ES/BS demonstrated opposite trends during the healing period. Immediate loading with light forces did not negatively affect the bone healing pattern.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom