Influence of ceramic and stainless steel brackets on the notching of archwires during clinical treatment
Author(s) -
Laurence C. Articolo
Publication year - 2000
Publication title -
european journal of orthodontics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.252
H-Index - 84
eISSN - 1460-2210
pISSN - 0141-5387
DOI - 10.1093/ejo/22.4.409
Subject(s) - bracket , notching , materials science , premolar , molar , ceramic , scanning electron microscope , dentistry , incisor , composite material , orthodontics , metallurgy , medicine , structural engineering , engineering
The surface topography of 100 clinically used archwires of stainless steel, beta-, or nickel-titanium were investigated that had contacted either ceramic or stainless steel brackets. One group consisted of two sets: 60 wires with no treatment records accessed to bias analyses, and 40 wires for which extensive clinical records were available, half of which were used with ceramic or stainless steel brackets. A control group consisted of two sets: 30 unused wires comprised of five round and rectangular wires of each alloy, and four wires that were ligated and immediately removed from patients' mouths. After ultrasonic cleaning, each wire was inspected under an optical and/or a scanning electron microscope. Notches were categorized with regard to frequency, patterns, and severity, and mapped as a function of wire aspect (lingual, facial, and occlusal/gingival) and anatomical regions (molar, premolar, canine, and incisor). From these data the average severity of notch patterns and a notching index were derived. Although no recognizable defect patterns were observed in the control group, seven basic patterns were recognized for each wire cross-sectional shape in the clinically used wires. These wires appeared most damaged on their lingual aspect and least damaged on their facial aspect. With regard to anatomical regions, notching was prevalent in the anterior regions and sparse in the molar regions. The notch activity and the severity were nearly three times greater from ceramic brackets than from stainless steel brackets. Over one-third of all notches documented in ceramic bracket cases had severity numbers of 3 and penetrated at least one-quarter of each wire's dimension, However, over two-thirds of all notches documented in stainless steel bracket cases had severity numbers of 1. From these tabulations a theory of notch formation was proposed in which vertical movement from tooth or wire during mastication caused fretting wear, and horizontal movement during orthodontic procedures such as space closure, tipping, or bodily movement caused sliding wear.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom