Universal implantation of temporary epicardial pacing wires after surgery for congenital heart disease: necessity or luxury?
Author(s) -
Gopinath Perumal,
Supreet P Marathe,
Kim Betts,
Jessica Suna,
J. Morwood,
J Wildschut,
Adrian Mattke,
Nelson Alphonso,
Prem Venugopal
Publication year - 2019
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1093/ejcts/ezz285
Subject(s) - medicine , hemodynamics , cardiopulmonary bypass , heart disease , cardiology , cardiac surgery , surgery , anesthesia
OBJECTIVES Routine implantation of temporary epicardial pacing wires after surgery for congenital heart disease (CHD) has recently been questioned. We evaluated the incidence of arrhythmias, arrhythmias causing haemodynamic compromise and the safety of a strategy of selective implantation of pacing wires in our unit. METHODS All patients who underwent surgery for CHD using cardiopulmonary bypass between September 2015 and December 2016 were retrospectively enrolled in the study (n = 313). Patients were stratified into group A (universal implantation) and group B (selective implantation). Group B received pacing wires only when postoperative rhythm disturbances were anticipated based on the operating surgeon’s judgement. The primary outcome was arrhythmia causing haemodynamic compromise. Outcomes were compared between unmatched and propensity matched groups. RESULTS Forty-eight patients experienced an arrhythmia causing haemodynamic compromise (15.3%). Twenty-three patients (7.3%) experienced an arrhythmia causing haemodynamic compromise that required the use of pacing wires for therapeutic purposes (group A n = 13, group B n = 10, P = 0.34). There were no pacing wire related complications in either group. All patients in group A and 90% in group B had pacing wires when needed (P = 0.435). In group A, 89% of patients had pacing wires which were not used compared with 13% in group B (P < 0.001). Results were unchanged when repeated using propensity matching (81 pairs). CONCLUSIONS The probability of developing a postoperative arrhythmia requiring therapeutic pacing can be predicted using the risk factors identified in our study. The routine implantation of pacing wires after surgery for CHD is not necessary. A measured reduction from universal implantation is safe.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom