z-logo
open-access-imgOpen Access
An 18-month comparison of clinical outcomes between continuous-flow left ventricular assist devices
Author(s) -
Osnat Itzhaki Ben Zadok,
Ben BenAvraham,
Aviv A. Shaul,
Yoav Hammer,
Victor Rubachevski,
Dan Aravot,
Ran Kornowski,
Tuvia BenGal
Publication year - 2019
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1093/ejcts/ezz268
Subject(s) - interquartile range , medicine , hazard ratio , confidence interval , destination therapy , ventricular assist device , continuous flow , cardiology , stroke (engine) , surgery , heart failure , mechanical engineering , physics , mechanics , engineering
OBJECTIVES In this study, we aimed to determine the comparative outcomes of patients supported with continuous-flow left ventricular assist devices (LVADs): HeartMate 2 (HM2), HeartWare (HW) and HeartMate 3 (HM3) in a real-world setting. METHODS The study was an investigator-initiated comparative retrospective analysis of patients who underwent continuous-flow LVAD implantation at our institution between 2008 and 2017. The follow-up duration was 18 months after implantation. RESULTS The study included 105 continuous-flow LVAD-supported patients of whom 51% (n = 54), 24% (25) and 25% (26) underwent implantation of HM2, HW and HM3, respectively. During follow-up, patients who were supported with HM3 versus either HM2 or HW LVADs demonstrated a lower risk of stroke (0% vs 26%, P < 0.001 and 0% vs 40%, P < 0.001, respectively) and lower rates of thrombosis (0% vs 31%, P < 0.001 and 0% vs 12%, P < 0.001, respectively), findings that were consistent with their calculated haemocompatibility scores (cumulative score 5, 89 and 56 for HM3, HM2 and HW, respectively, P < 0.001). Moreover, patients supported with HM3 versus HW had fewer unplanned hospitalizations [median 1 (25th–75th interquartile range 0–2) vs 3 (interquartile range 2–4), P = 0.012]. Importantly, survival free from stroke or device exchange was higher in patients supported with HM3 compared with either the HM2 or the HW LVADs [hazard ratio (HR) 2.77, confidence interval (CI) 1.13–6.78; P = 0.026 and HR 2.70, CI 1.01–7.20; P = 0.047, respectively]. CONCLUSIONS HM3 device currently presents better prognostic and adverse events profiles when compared with the HM2 or the HW LVADs. A larger-scale head-to-head comparison between the devices is warranted in order to confirm our findings.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom