z-logo
open-access-imgOpen Access
Incidence, predictors and cerebrovascular consequences of leaflet thrombosis after transcatheter aortic valve implantation: a systematic review and meta-analysis
Author(s) -
Fabrizio D’Ascenzo,
Stefano Salizzoni,
Andrea Saglietto,
Martina Cortese,
Azeem Latib,
Anna Franzone,
Marco Barbanti,
Fabian Nietlispach,
Erik W. Holy,
Gaetano Burriesci,
Alessandro De Paoli,
Paolo Fonio,
Francesco Atzeni,
Claudio Moretti,
Leor Perl,
Maurizio D’Amico,
Mauro Rinaldi,
Federico De Marco
Publication year - 2019
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1093/ejcts/ezz099
Subject(s) - cardiology , meta analysis , leaflet (botany) , medicine , incidence (geometry) , thrombosis , stroke (engine) , aortic valve , engineering , mechanical engineering , physics , optics , paleontology , biology
OBJECTIVES We examined the incidence, the impact of subsequent cerebrovascular events and the clinical or procedural predictors of leaflet thrombosis (LT) in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS MEDLINE/PubMed was systematically screened for studies reporting on LT in TAVI patients. Incidence [both clinical and subclinical, i.e. detected with computed tomography (CT)] of LT was the primary end point of the study. Predictors of LT evaluated at multivariable analysis and impact of LT on stroke were the secondary ones. RESULTS Eighteen studies encompassing 11 124 patients evaluating incidence of LT were included. Pooled incidence of LT was 0.43% per month [5.16% per year, 95% confidence interval (CI) 0.21–0.72, I2 = 98%]. Pooled incidence of subclinical LT was 1.36% per month (16.32% per year, 95% CI 0.71–2.19, I2 = 94%). Clinical LT was less frequent (0.04% per month, 0.48% per year, 95% CI 0.00–0.19, I2 = 93%). LT increased the risk of stroke [odds ratio (OR) 4.21, 95% CI 1.27–13.98], and was more frequent in patients with a valve diameter of 28-mm (OR 2.89: 1.55–5.8), for balloon-expandable (OR 8: 2.1–9.7) or after valve-in-valve procedures (OR 17.1: 3.1–84.9). Oral anticoagulation therapy reduced the risk of LT (OR 0.43, 95% CI: 0.22–0.84, I2 = 64%), as well as the mean transvalvular gradient. CONCLUSIONS LT represents an infrequent event after TAVI, despite increasing risk of stroke. Given its full reversal with warfarin, in high-risk patients (those with valve-in-valve procedures, balloon expandable or large-sized devices), a protocol which includes a control CT appears reasonable.