z-logo
open-access-imgOpen Access
Which is the best prosthesis in an isolated or combined tricuspid valve replacement?
Author(s) -
Peng Liu,
Dongsheng Xia,
Weihua Qiao,
Dan Hu,
Adnan Ahmed,
Nianguo Dong,
Si Chen
Publication year - 2020
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1093/ejcts/ezaa273
Subject(s) - tricuspid valve , medicine , prosthesis , surgery , mechanical valve , thrombosis , valve replacement , cardiology , stenosis
OBJECTIVES The debate concerning the optimal choice of tricuspid position continues. We compared the long-term results of mechanical and biological prostheses in patients who underwent isolated or combined tricuspid valve replacement, at 2 major cardiac surgical centres in central China. METHODS From January 1999 to December 2018, 338 patients underwent tricuspid valve replacement. Patients were divided into an isolated group or a combined group according to whether their surgery was combined with a left heart valve surgery. Mechanical tricuspid valve replacement was performed in 142 patients (isolated group: 41 vs combined group: 101), and 196 patients underwent bioprosthetic tricuspid valve replacement (isolated group: 145 vs combined group: 51). Operative results, long-term survival and tricuspid valve-related events were compared. RESULTS Early mortality in the combined group was higher (n = 6, 4%) than that in the isolated group (n = 3, 2%), but no significant difference was observed between the mechanical and biological subgroups. In the isolated group, there was a higher event-free rate in the biological subgroup than in the mechanical subgroup (P = 0.042) and a similar result was also observed for patients without Ebstein’s anomaly (P = 0.039). In the combined group, no significant difference was observed (P = 0.98). Survival rates were similar between the mechanical and biological subgroups in both the isolated (P = 0.54) and combined (P = 0.81) groups. Mechanical valves in isolated tricuspid valve replacement were more prone to valve thrombosis and bleeding. CONCLUSIONS Every decision regarding tricuspid valve prostheses should be individualized, but biological prostheses may be an optimal choice for patients, especially for patients without Ebstein’s anomaly, in isolated tricuspid valve replacement.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom