z-logo
open-access-imgOpen Access
Comparison between lung perfusion scan and single-photon emission computed tomography/computed tomography for predicting postoperative lung function after pulmonary resection in patients with borderline lung function
Author(s) -
Kwon Joong Na,
Samina Park,
Hyun Joo Lee,
In Kyu Park,
Chang Hyun Kang,
Young Tae Kim
Publication year - 2020
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1093/ejcts/ezaa211
Subject(s) - concordance , dlco , medicine , nuclear medicine , perfusion , concordance correlation coefficient , single photon emission computed tomography , lung , pulmonary function testing , tomography , perfusion scanning , emission computed tomography , spirometry , high resolution computed tomography , correlation , computed tomography , radiology , diffusing capacity , lung function , mathematics , statistics , asthma , geometry
OBJECTIVES We compared the usefulness of single-photon emission computed tomography/computed tomography (SPECT/CT) and lung perfusion scintigraphy (LPS) for predicting postoperative lung function by comparing patients with borderline lung function. METHODS A total of 274 patients who underwent simultaneous LPS and SPECT/CT and had a forced expiratory volume in 1 s (FEV1) or diffusing capacity for carbon monoxide (DLCO) under 80% were included. The % uptake by LPS was calculated by the posterior-oblique method. The concordance and difference of the % uptake, predicted postoperative (ppo) FEV1 and ppoDLCO as determined by 2 methods were evaluated. The association between ppo values and actual postoperative FEV1 and DLCO was examined. Subgroup analysis was conducted in redo-operation cases. RESULTS The % uptake of each lobe, except the right middle lobe, showed fair concordance (concordance correlation coefficients for right upper, middle, lower, left upper and lower lobe = 0.61, 0.37, 0.71, 0.66 and 0.69, respectively). ppoFEV1 and ppoDLCO also revealed high concordance between both methods (concordance correlation coefficient = 0.93 for ppoFEV1 and concordance correlation coefficient = 0.92 for ppoDLCO) without a significant difference (P = 0.42 for ppoFEV1; P = 0.31 for ppoDLCO). Both ppoFEV1 and ppoDLCO showed a significantly high correlation with the actual FEV1 (r = 0.77, P < 0.01 for LPS, r = 0.77, P < 0.01 for SPECT/CT) and DLCO (r = 0.62, P < 0.01 for LPS, r = 0.62, P < 0.01 for SPECT/CT). High concordance of % uptake, ppoFEV1 and ppoDLCO was present in redo-operation patients. CONCLUSIONS Both LPS and SPECT/CT showed high predictability for actual postoperative lung function, and LPS showed good performance to estimate ppoFEV1 and ppoDLCO with reference to SPECT/CT, even in redo-operation cases.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom