Blood stream infection and outcomes in recipients of a left ventricular assist device
Author(s) -
Philipp Angleitner,
Aleksa Matic,
Alexandra Kaider,
Kamen Dimitrov,
Sigrid Sandner,
Dominik Wiedemann,
Julia Riebandt,
Thomas Schlöglhofer,
Günther Laufer,
Daniel Zimpfer
Publication year - 2020
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1093/ejcts/ezaa153
Subject(s) - medicine , ventricular assist device , cardiology , hazard ratio , extracorporeal membrane oxygenation , stroke (engine) , heart transplantation , thrombus , proportional hazards model , confidence interval , destination therapy , transplantation , surgery , heart failure , mechanical engineering , engineering
OBJECTIVES Our aim was to investigate associations between blood stream infection [≥1 positive blood culture (BC)] and outcomes in recipients of a left ventricular assist device (LVAD). METHODS We retrospectively analysed all adult recipients of a continuous-flow LVAD between 2006 and 2016 at the Division of Cardiac Surgery, Medical University of Vienna (n = 257; devices: Medtronic HeartWare® HVAD®, Abbott HeartMate II®, Abbott HeartMate 3™). The primary outcome was all-cause mortality during follow-up. Secondary outcomes included the risk of stroke and pump thrombus during follow-up as well as the probability of heart transplantation (HTx). Risk factors for the development of ≥1 positive BC were evaluated additionally. RESULTS The incidence of ≥1 positive BC during the first year of LVAD support was 32.1% [95% confidence interval (CI) 26.4–37.9]. Multivariable Cox proportional cause-specific hazards regression analysis showed that a positive BC was associated with significantly increased all-cause mortality [hazard ratio (HR) 5.51, 95% CI 3.57–8.51; P < 0.001]. Moreover, a positive BC was associated with a significantly increased risk of stroke (HR 2.41, 95% CI 1.24–4.68; P = 0.010). There was no association with the risk of pump thrombus or the probability of HTx. Independent risk factors for a positive BC included preoperative albumin and extracorporeal membrane oxygenation/intra-aortic balloon pump support. CONCLUSIONS Blood stream infection is common and associated with a significantly increased risk of all-cause mortality and stroke at any given time during LVAD support. Effective strategies of prevention and treatment are necessary.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom