Feasibility and effectiveness of laparoscopic transgastric stapler-assisted circumferential esophageal mucosectomy and simultaneous fundoplication in a pig model
Author(s) -
Daniel C. Steinemann,
Philip C. Müller,
A-C Schwarz,
Andreas Zerz,
Georg R. Linke,
Beat P. MüllerStich
Publication year - 2018
Publication title -
diseases of the esophagus
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.115
H-Index - 63
eISSN - 1442-2050
pISSN - 1120-8694
DOI - 10.1093/dote/doy030
Subject(s) - medicine , reflux , esophagus , surgery , nissen fundoplication , gerd , laparoscopy , disease
Laparoscopic transgastric stapler-assisted mucosectomy (SAM) has been described for minimally invasive circumferential en bloc resection of Barrett's esophagus (BE). Conceivably long-term disease control might be achieved by adding antireflux surgery after resection of BE by SAM. The aim of this study was to assess the feasibility of combined SAM and fundoplication in one laparoscopic procedure in six pigs. Furthermore, the competence of the gastroesophageal junction (GEJ) was assessed at baseline, after SAM, and after subsequent laparoscopic fundoplication. At each measuring point reflux measurements were repeated 6 times in each pig. Blue-colored water was infused into the stomach to provoke reflux. Intragastric yield pressure and volume were recorded until drainage of blue solution (DBS) was noted. Time to reflux was measured by DBS and by multichannel intraluminal impedance (MII). In all animals SAM followed by laparoscopic fundoplication was feasible in a single session. A weakening of the GEJ was found after SAM, indicated by decreased yield pressure (11.5 mmHg vs. 8.5 mmHg; P < 0.001), time to DBS (90 seconds vs. 60 seconds; P = 0.008) and MII (80 seconds vs. 33 seconds; P < 0.001). After additional Nissen fundoplication the GEJ competence was restored, with measurements returning to baseline values (time to DBS 99 seconds; P = 0.15; MII 76 seconds; P = 0.84). The yield pressure increased from 11.5 mmHg at baseline to 19.7 mmHg after SAM and fundoplication (P < 0.001). Laparoscopic fundoplication and SAM may be combined in a single laparoscopic session. Although the GEJ was weakened after SAM, Nissen fundoplication restored the GEJ as an effective reflux barrier in this experiment. For clinical validation, the results need to be confirmed in a prospective human trial.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom