Rapid Determination of Transferrin Isoforms by Immunoaffinity Liquid Chromatography and Electrospray Mass Spectrometry
Author(s) -
Jean M. Lacey,
H. Robert Bergen,
Mark J Magera,
Stephen Naylor,
John F. O’Brien
Publication year - 2001
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1093/clinchem/47.3.513
Subject(s) - oligosaccharide , chemistry , chromatography , transferrin , sialic acid , mass spectrometry , isoelectric focusing , gene isoform , glycosylation , isoelectric point , biochemistry , enzyme , gene
BACKGROUNDCongenital disorders of glycosylation (CDG) are autosomal recessive disorders that produce increased serum carbohydrate-deficient transferrin (CDT) isoforms. Methods to resolve CDT from fully glycosylated transferrin (Trf) have been based on a neutral shift in the isoelectric focusing (IEF) pattern or on a reduction in the negative charge, allowing resolution by anion-exchange chromatography. Our purpose was to develop a method of resolution and relative quantification of Trf isoforms using online immunoaffinity liquid chromatography-mass spectrometry (LC-MS).METHODSSerum (25 microL) was diluted with 100 microL of water before application to an immunoaffinity column that sequestered Trf isoforms. Trf isoforms were eluted from the immunoaffinity column, concentrated on a C4 column, eluted from the C4 column, and introduced into the mass spectrometer. Analysis of the Trf isoforms was entirely automated and completed in <10 min per sample.RESULTSThe LC-MS method demonstrated that the major abnormal Trf isoforms in CDG lack one complete oligosaccharide structure (mono-oligosaccharide) or both oligosaccharide structures (a-oligosaccharide), but not the sialic acids, as presumed on the basis of IEF methods. Calculation of relative ratios among three possible species (mono-/di-oligosaccharide and a-/di-oligosaccharide) is reproducible [mean intra- and interassay CVs were 9.3% (n = 10) and 10% (n = 5), respectively]. A reference range for patients <18 years was determined by analysis of 209 samples (for mono-/di-oligosaccharide, the median was 0.041 and the range was 0.018-0.083; for a-/di-oligosaccharide, the median was 0.007 and the range was 0.002-0.036). Comparison of data obtained with an affinity chromatography-IEF method and the LC-MS method demonstrated equivalence in the interpreted results (n = 170).CONCLUSIONSAdvantages of the LC-MS method include improved sensitivity, minimal sample preparation, and an analysis time of <10 min. The method was automated, which allowed high throughput, with >100 samples analyzed in a single day. Moreover, the nature of the oligosaccharide defect in CDG is accurately reflected by mass resolution, and subtle oligosaccharide truncations may also be detected by this method.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom