z-logo
open-access-imgOpen Access
Development of a Routine Method for the Determination of Trace Metals in Whole Blood by Magnetic Sector Inductively Coupled Plasma Mass Spectrometry with Particular Relevance to Patients with Total Hip and Knee Arthroplasty
Author(s) -
C. Patrick Case,
Lyndon A. Ellis,
Justine Clare Turner,
Ben Fairman
Publication year - 2001
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1093/clinchem/47.2.275
Subject(s) - cobalt , inductively coupled plasma mass spectrometry , chemistry , chromium , whole blood , nickel , molybdenum , inductively coupled plasma , chromatography , atomic absorption spectroscopy , analyte , resolution (logic) , mass spectrometry , analytical chemistry (journal) , inorganic chemistry , surgery , plasma , medicine , physics , organic chemistry , computer science , artificial intelligence , quantum mechanics
BACKGROUNDJoint-replacement surgery has revolutionized the treatment of osteoarthritis and is still the most effective therapy. A recent clinical trend reintroducing metal-on-metal bearing surfaces has in turn stimulated a requirement for accurate measurement of the concentrations of relevant metals in both pre- and postoperative patients. Thus, there is a need for cost-effective, multielement methods for trace metal analysis in whole blood to monitor possible increases in wear metal concentrations.METHODSA method was developed to allow routine analysis of whole blood samples for molybdenum, cobalt, chromium, and nickel. Sample preparation consisted of a simple 1:10 dilution of whole blood with a solution of 10 mL/L Triton X-100, 0.0002 mol/L EDTA, and 0.01 mol/L ammonium hydroxide. Final determination was performed by a double-focusing magnetic sector inductively coupled plasma mass spectrometer operated in medium-resolution mode (resolution, 3400). Online addition of rhodium was used for internal standardization.RESULTSDetection limits in whole blood were 0.06 microg/L for chromium, cobalt, and molybdenum and 0.30 microg/L for nickel. Base concentrations of 0.22, 0.17, 0.62, and 0.99 microg/L for chromium, cobalt, molybdenum, and nickel, respectively, in whole blood have been found. Polyatomic interferences on all four elements have been shown to be resolved from the analyte masses by use of a resolution of >3000.CONCLUSIONSThe simple, rapid method of sample preparation is effective in minimizing potential contamination and enables 60 samples (run time, 8 h) to be analyzed before cleaning the instrument is necessary. A resolution >3000 was sufficient to separate polyatomic interferences from the masses of interest. The method was used to analyze a large number of blood samples taken from primary patients awaiting total hip arthroplasty. The method is sensitive enough to provide base concentrations for chromium, cobalt, and molybdenum in whole blood. The results for nickel were compromised by high signals for blank samples.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom