z-logo
open-access-imgOpen Access
False Positivity in a Cyto-ELISA for Anti-Endothelial Cell Antibodies Caused by Heterophile Antibodies to Bovine Serum Proteins
Author(s) -
R Révélen,
Anne Bordron,
Maryvonne Dueymes,
Pierre Youinou,
J Arvieux
Publication year - 2000
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1093/clinchem/46.2.273
Subject(s) - antibody , bovine serum albumin , microbiology and biotechnology , chemistry , heterophile , fetal bovine serum , cell culture , serial dilution , cell , biology , immunology , chromatography , medicine , biochemistry , pathology , genetics , alternative medicine
BACKGROUNDELISAs with fixed endothelial cells or cell lines are widely used screening tests for anti-endothelial cell antibodies (AECAs), but spurious increases occur. We examined interferences by heteroantibodies and means to eliminate them.METHODSAECAs were measured by ELISA on fixed layers of the human endothelial cell line, EA.hy 926, in a panel of 60 patient serum samples diluted in bovine serum albumin. Heteroantibodies against fetal calf serum (FCS) proteins were demonstrated and characterized in an ELISA-the interference assay-that used FCS-coated plates and Tween 20-containing buffer as blocking agent and sample diluent, as well as by immunoblotting.RESULTSIn 12 of 60 patient serum samples, spurious increases of AECA titers were produced by endogenous antibodies reacting with FCS proteins from culture medium that were coated onto the solid-phase at the time of cell plating. This mechanism of interference was supported experimentally by exposing extracellular matrix, varying cell density, and incubating wells with FCS alone. The heterophile antibodies were mainly IgG and IgA, and in inhibition experiments, they recognized serum proteins from goat, sheep, and horse. Washing cells free of FCS before plating, or adding FCS (100 mL/L) to the patient sample diluent eliminated spurious signals from all 30 tested sera, but the latter method had practical advantages.CONCLUSIONSAntibodies against animal serum proteins are a frequent cause of erroneous results in cyto-ELISAs. The interference can be eliminated by simple antibody absorption in FCS-containing dilution buffer.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom