z-logo
open-access-imgOpen Access
Activated Protein C Resistance: Automated Detection of the Factor V Leiden Mutation by Mismatch Hybridization
Author(s) -
Karl Klingler,
Thomas Junold,
Klaus Wielckens
Publication year - 1999
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1093/clinchem/45.11.1925
Subject(s) - biotinylation , oligonucleotide , biotin , dna , mutation , microbiology and biotechnology , primer (cosmetics) , point mutation , streptavidin , genetics , biology , chemistry , gene , organic chemistry
BACKGROUNDA single point mutation in the factor V gene has been demonstrated to be the cause of factor Va resistance to proteolytic cleavage by activated protein C. Knowledge of the patient's genetic disposition is of great importance in situations such as pregnancy, surgery, use of oral contraceptives, and immobilization.METHODSWe have developed a rapid, automated test for the detection of the factor V mutation that makes use of differences in thermal stability between perfect-match and non-perfect-match hybrids. A DNA fragment spanning the mutation is amplified with a biotin-labeled primer. Ruthenium-labeled oligonucleotides, perfectly matching either the biotinylated wild-type strand or the biotinylated mutation strand, are added. Heating to 95 degrees C and subsequent cooling lead to the formation of double-stranded DNA. Under the conditions chosen, ruthenium-labeled oligonucleotides form stable, double-stranded DNA with the biotinylated strand only if both strands perfectly match each other. The ruthenium signal is measured on a modified Elecsys 1010 system (Roche Diagnostics).RESULTSThe ratio between the signals obtained with perfectly matching and non-perfectly matching oligonucleotides reflects the genetic status. Analyzed samples can be divided into three nonoverlapping groups based on these ratios. We confirmed the reliability of the method by analyzing several samples of known genetic status; the results were identical in every single instance.CONCLUSIONSThe test discriminates unambiguously between the heterozygous and the homozygous states. Because of its low costs and easy handling, the assay is suitable for use in routine laboratories of clinical chemistry.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom