Derivative Quotient Spectrophotometry and an Eco-Friendly Micellar Chromatographic Approach with Time-Programmed UV-Detection for the Separation of Two Fluoroquinolones and Phenazopyridine
Author(s) -
Manar M. Tolba,
Mohamed M. Salim
Publication year - 2016
Publication title -
journal of chromatographic science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.362
H-Index - 56
eISSN - 1945-239X
pISSN - 0021-9665
DOI - 10.1093/chromsci/bmw010
Subject(s) - chemistry , chromatography , analyte , elution , detection limit , triethylamine , micellar liquid chromatography , spectrophotometry , derivative (finance) , aqueous solution , micelle , organic chemistry , economics , financial economics
In this study, two analytical approaches were exploited for the resolution of binary mixtures of ciprofloxacin HCl (CIP) or norfloxacin (NOR) and phenazopyridine HCl (PHZ). In the first approach, the amplitudes of the first derivative of the ratio spectra were measured at 267 or 287 nm for CIP and at 268 or 291 nm for NOR. PHZ could be directly determined in the presence of CIP or NOR at 405 nm. The calibration graphs were rectilinear over the ranges of 1.0-16.0 µg/mL for CIP or NOR and 1.0-10.0 µg/mL for PHZ. In the second approach, an accurate, reliable and environmentally nontoxic micellar liquid chromatographic (MLC) method was developed. A good chromatographic separation was achieved using a 150 mm × 4.6 mm i.d., 5 µm particle size Spherisorb ODS-2 column. Eco-friendly mobile phase containing 0.12 M sodium dodecyl sulphate, 0.3% triethylamine and 6%n-butanol in 0.02 M orthophosphoric acid of pH 3.0 was pumped at a flow rate of 1 mL/min. Time programmed UV-detection was applied to allow sensitive determination of the studied drugs. The analytes were eluted without interferences in <10 min. Methocarbamol was used as an internal standard. The MLC method was found to be rectilinear over the concentration range of 0.5-20.0 μg/mL for CIP, NOR or PHZ. These optimized and validated methods were successfully applied for the simultaneous analysis of the studied drugs in their synthetic mixtures and co-formulated tablets. Moreover, the second method was further extended to the determination of these drugs in human urine with direct injection and without any pretreatment.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom