Improved description of ligand polarization enhances transferability of ion–ligand interactions
Author(s) -
Vered WinemanFisher,
Yasmine S. Al-Hamdani,
Péter R. Nagy,
Alexandre Tkatchenko,
Sameer Varma
Publication year - 2020
Publication title -
the journal of chemical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.071
H-Index - 357
eISSN - 1089-7690
pISSN - 0021-9606
DOI - 10.1063/5.0022058
Subject(s) - transferability , ion , chemistry , polarization (electrochemistry) , calibration , ligand (biochemistry) , computational chemistry , biological system , chemical physics , computer science , physics , machine learning , quantum mechanics , biochemistry , receptor , organic chemistry , logit , biology
The reliability of molecular mechanics (MM) simulations in describing biomolecular ion-driven processes depends on their ability to accurately model interactions of ions simultaneously with water and other biochemical groups. In these models, ion descriptors are calibrated against reference data on ion-water interactions, and it is then assumed that these descriptors will also satisfactorily describe interactions of ions with other biochemical ligands. The comparison against the experiment and high-level quantum mechanical data show that this transferability assumption can break down severely. One approach to improve transferability is to assign cross terms or separate sets of non-bonded descriptors for every distinct pair of ion type and its coordinating ligand. Here, we propose an alternative solution that targets an error-source directly and corrects misrepresented physics. In standard model development, ligand descriptors are never calibrated or benchmarked in the high electric fields present near ions. We demonstrate for a representative MM model that when the polarization descriptors of its ligands are improved to respond to both low and high fields, ligand interactions with ions also improve, and transferability errors reduce substantially. In our case, the overall transferability error reduces from 3.3 kcal/mol to 1.8 kcal/mol. These improvements are observed without compromising on the accuracy of low-field interactions of ligands in gas and condensed phases. Reference data for calibration and performance evaluation are taken from the experiment and also obtained systematically from "gold-standard" CCSD(T) in the complete basis set limit, followed by benchmarked vdW-inclusive density functional theory.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom