z-logo
open-access-imgOpen Access
Invited Article: A rigid coherent anti-Stokes Raman scattering endoscope with high resolution and a large field of view
Author(s) -
Peyman Zirak,
Gregor Matz,
Bernhard Messerschmidt,
Tobias Meyer,
Michael Schmitt,
Jürgen Popp,
Ortrud Uckermann,
Roberta Galli,
Matthias Kirsch,
Martin Winterhalder,
Andreas Zumbusch
Publication year - 2018
Publication title -
apl photonics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.094
H-Index - 34
ISSN - 2378-0967
DOI - 10.1063/1.5027182
Subject(s) - endoscope , optics , raman scattering , characterization (materials science) , field (mathematics) , computer science , image resolution , endoscopy , lens (geology) , physics , medical physics , raman spectroscopy , biomedical engineering , radiology , medicine , mathematics , pure mathematics
Nonlinear optical endoscopy is an attractive technique for biomedical imaging since it promises to give access to high resolution imaging in vivo. Among the various techniques used for endoscopic contrast generation, coherent anti-Stokes Raman scattering (CARS) is especially interesting. CARS endoscopy allows molecule specific imaging of unlabeled samples. In this contribution, we describe the design, implementation, and experimental characterization of a rigid, compact CARS endoscope with a spatial resolution of 750 nm over a field of view of roughly 250 μm. Omission of the relay optics and use of a gradient index lens specifically designed for this application allow one to realize these specifications in an endoscopic unit which is 2.2 mm wide over a length of 187 mm, making clinical applications during surgical interventions possible. Multimodal use of the endoscope is demonstrated with images of samples with neurosurgical relevance.Nonlinear optical endoscopy is an attractive technique for biomedical imaging since it promises to give access to high resolution imaging in vivo. Among the various techniques used for endoscopic contrast generation, coherent anti-Stokes Raman scattering (CARS) is especially interesting. CARS endoscopy allows molecule specific imaging of unlabeled samples. In this contribution, we describe the design, implementation, and experimental characterization of a rigid, compact CARS endoscope with a spatial resolution of 750 nm over a field of view of roughly 250 μm. Omission of the relay optics and use of a gradient index lens specifically designed for this application allow one to realize these specifications in an endoscopic unit which is 2.2 mm wide over a length of 187 mm, making clinical applications during surgical interventions possible. Multimodal use of the endoscope is demonstrated with images of samples with neurosurgical relevance.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom