z-logo
open-access-imgOpen Access
Design of the klystron filament power supply control system for EAST LHCD
Author(s) -
Zege Wu,
Mao Wang,
Huaichuan Hu,
Wendong Ma,
Taian Zhou,
Faxin Zhou,
F. K. Liu,
Jiafang Shan
Publication year - 2016
Publication title -
aip advances
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.421
H-Index - 58
ISSN - 2158-3226
DOI - 10.1063/1.4962492
Subject(s) - klystron , protein filament , electrical engineering , nuclear engineering , power (physics) , physics , engineering , materials science , quantum mechanics , composite material
A filament is a critical component of the klystron used to heat the cathode. There are totally 44 klystrons in experimental advanced superconducting tokamak (EAST) lower hybrid current drive (LHCD) systems. All klystron filaments are powered by AC power suppliers through isolated transformers. In order to achieve better klystron preheat, a klystron filament power supply control system is designed to obtain the automatic control of all filament power suppliers. Klystron filament current is measured by PLC and the interlock between filament current and klystron high voltage system is also implemented. This design has already been deployed in two LHCD systems and proves feasible completely