A piezoelectric cryogenic heat switch
Author(s) -
Amir E. Jahromi,
Dan Sullivan
Publication year - 2014
Publication title -
review of scientific instruments
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.605
H-Index - 165
eISSN - 1089-7623
pISSN - 0034-6748
DOI - 10.1063/1.4876483
Subject(s) - piezoelectricity , conductance , materials science , thermal conductivity , cryogenics , thermal , heat pipe , optoelectronics , thermodynamics , composite material , heat transfer , condensed matter physics , physics
We have measured the thermal conductance of a mechanical heat switch actuated by a piezoelectric positioner, the PZHS (PieZo electric Heat Switch), at cryogenic temperatures. The thermal conductance of the PZHS was measured between 4 K and 10 K, and on/off conductance ratios of about 100-200 at lowest and highest measures temperature were achieved when the positioner applied its maximum force of 8 N, respectively. We discuss the advantages of using this system in cryogenic applications, and estimate the ultimate performance of an ideal PZHS.