z-logo
open-access-imgOpen Access
Making a commercial atomic force microscope more accurate and faster using positive position feedback control
Author(s) -
Iskandar Al-Thani Mahmood,
S. O. Reza Moheimani
Publication year - 2009
Publication title -
review of scientific instruments
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.605
H-Index - 165
eISSN - 1089-7623
pISSN - 0034-6748
DOI - 10.1063/1.3155790
Subject(s) - scanner , controller (irrigation) , compensation (psychology) , pid controller , piezoelectricity , coupling (piping) , vibration , control theory (sociology) , computer science , microscope , acoustics , optics , temperature control , physics , control engineering , mechanical engineering , control (management) , artificial intelligence , engineering , psychology , agronomy , psychoanalysis , biology
This paper presents experimental implementation of a positive position feedback (PPF) control scheme for vibration and cross-coupling compensation of a piezoelectric tube scanner in a commercial atomic force microscope (AFM). The AFM is a device capable of generating images with extremely high resolutions down to the atomic level. It is also being used in applications that involve manipulation of matter at a nanoscale. Early AFMs were operated in open loop. Consequently, they were susceptible to piezoelectric creep, thermal drift, hysteresis nonlinearity, and scan-induced vibration. These effects tend to distort the generated image and slow down the scanning speed of the device. Recently, a new generation of AFMs has emerged that utilizes position sensors to measure displacements of the scanner in three dimensions. These AFMs are equipped with feedback control loops that work to minimize the adverse effects of hysteresis, piezoelectric creep, and thermal drift on the obtained image using proportional-plus-integral (PI) controllers. These feedback controllers are often not designed to deal with the highly resonant nature of an AFM's scanner nor with the cross coupling between various axes. In this paper we illustrate the improvement in accuracy and imaging speed that can be achieved by using a properly designed feedback controller such as a PPF controller. Such controllers can be incorporated into most modern AFMs with minimal effort since they can be implemented in software with the existing hardware. Experimental results show that by implementing the PPF control scheme, relatively good images in comparison with a well-tuned PI controller can still be obtained up to line scan of 60 Hz.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom