z-logo
open-access-imgOpen Access
He II heat exchanger test unit for the LHC inner triplet
Author(s) -
C. Darve
Publication year - 2002
Publication title -
aip conference proceedings
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.177
H-Index - 75
eISSN - 1551-7616
pISSN - 0094-243X
DOI - 10.1063/1.1472016
Subject(s) - large hadron collider , heat exchanger , nuclear engineering , fermilab , magnet , water cooling , thermal hydraulics , thermal , nuclear physics , physics , materials science , mechanical engineering , mechanics , thermodynamics , heat transfer , engineering
The Inner Triplet Heat Exchanger Test Unit (IT-HXTU) is a 30-m long thermal model designed at Fermilab, built in US industry, fully automated and tested at CERN as part of the US LHC program to develop the LHC Interaction Region quadrupole system. The cooling scheme of the IT-HXTU is based on heat exchange between stagnant pressurized He II in the magnet cold mass and saturated He II (two-phase) flowing in a heat exchanger located outside of and parallel to the cold mass. The purposes of this test are, among others, to validate the proposed cooling scheme and to define an optimal control strategy to be implemented in the future LHC accelerator. This paper discusses the results for the heat exchanger test runs and emphasizes the thermal and hydraulic behavior of He II for the inner triplet cooling scheme.