z-logo
open-access-imgOpen Access
Effects of storage time and temperature on highly multiparametric flow analysis of peripheral blood samples; implications for clinical trial samples
Author(s) -
Amelia Jerram,
Thomas V. Guy,
Lucinda Beutler,
Bavani Gunasegaran,
Ronald Sluyter,
Barbara Fazekas de St Groth,
Helen M. McGuire
Publication year - 2021
Publication title -
bioscience reports
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.938
H-Index - 77
eISSN - 1573-4935
pISSN - 0144-8463
DOI - 10.1042/bsr20203827
Subject(s) - peripheral blood , peripheral , flow (mathematics) , medicine , chemistry , mechanics , physics
We sought to determine the effect of time and temperature of blood sample storage before preparation of human peripheral blood mononuclear cells (PBMCs) by Ficoll-hypaque density gradient centrifugation. Blood samples from healthy donors were stored at room temperature (RT) or refrigerated at 4°C before preparation of PBMCs. Cell yield and viability, and proportions of major cell populations within PBMCs, as determined by fluorescence flow cytometry, were assessed for both fresh and cryopreserved samples. Highly multiparametric mass cytometry was performed on cryopreserved PBMCs. We found that refrigeration had marked negative effects on subsequent PBMC yield. Storage at RT led to co-purification of low density neutrophils with PBMCs, but had no detectable effects on the proportions of multiple cell subsets including, but not limited to, monocytes, NK cells, B cells, Treg cells, and naïve, central memory and effector memory CD4+ and CD8+ T cells and CD45RA-positive terminal effector CD8+ T cells. Expression of a number of cell surface receptors, including CXCR5, CCR6, CXCR3 and TIGIT, but not CD247 was reduced after RT storage before PBMC preparation, and this effect correlated with the degree of low density neutrophil contamination. As such, when PBMC preparation cannot be undertaken immediately after blood draw, storage at RT is far superior to refrigeration. RT storage leads to neutrophil activation, but does not compromise measurement of PBMC subset distribution. However caution must be applied to interpretation of cytometric measurements of surface molecules such as chemokine receptors.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom