A multiplex loop-mediated isothermal amplification assay for rapid screening of Acinetobacter baumannii and D carbapenemase OXA-23 gene
Author(s) -
Rungong Yang,
Honghong Zhang,
Xiaoxia Li,
Ling Ye,
Meiliang Gong,
Jinghui Yang,
Jihong Yu,
Jie Bai
Publication year - 2018
Publication title -
bioscience reports
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.938
H-Index - 77
eISSN - 1573-4935
pISSN - 0144-8463
DOI - 10.1042/bsr20180425
Subject(s) - acinetobacter baumannii , multiplex , microbiology and biotechnology , multiplex polymerase chain reaction , loop mediated isothermal amplification , drug resistance , primer (cosmetics) , biology , polymerase chain reaction , gene , bacteria , dna , chemistry , pseudomonas aeruginosa , genetics , organic chemistry
Background : Acinetobacter baumannii is a health burden responsible for various nosocomial infections, and bacteremia in particular. The resistance of A. baumannii to most antibiotics including carbapenem has increased. OXA-23-producing A. baumannii is the chief source of nosocomial outbreaks with carbapenem-resistant A. baumannii Successful antibiotic treatment relies on the accurate and rapid identification of infectious agents and drug resistance. Here, we describe a multiplex loop-mediated isothermal amplification (LAMP) assay for simultaneous and homogeneous identification for A. baumannii infection screening and drug-resistance gene detection. Methods : Four primer pairs were designed to amplify fragments of the recA gene of A. baumannii and the oxa-23 gene. The reaction with a 25 μl of final volume was performed at 63°C for 60 min. For comparative purposes, we used a traditional method of bacterial identification to evaluate assay efficacy. Results : The multiplex LAMP assay enables simultaneous and homogeneous detection of the recA gene of A. baumannii and the oxa-23 gene and requires less than 21 min with no pre-requisite for DNA purification prior to the amplification reaction. The detection is specific to A. baumannii , and the coincidence rate of the multiplex LAMP and the traditional method was 100%. Conclusions : Our data indicate that the multiplex LAMP assay is a rapid, sensitive, simultaneous and homogeneous method for screening of A. baumannii and its drug-resistance gene.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom