z-logo
open-access-imgOpen Access
Removal of transition metals from rare earths by solvent extraction with an undiluted phosphonium ionic liquid: separations relevant to rare-earth magnet recycling
Author(s) -
Tom Vander Hoogerstraete,
Sil Wellens,
Katrien Verachtert,
Koen Binnemans
Publication year - 2013
Publication title -
green chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.221
H-Index - 221
eISSN - 1463-9270
pISSN - 1463-9262
DOI - 10.1039/c3gc40198g
Subject(s) - phosphonium , chemistry , cobalt , ionic liquid , extraction (chemistry) , inorganic chemistry , samarium , neodymium , chromatography , organic chemistry , catalysis , laser , physics , optics
An environmentally friendly process for the separation of the transition metals copper, cobalt, iron, manganese and zinc from rare earths by solvent extraction with the ionic liquid trihexyl(tetradecyl)phosphonium chloride has been developed. The solvent extraction process is carried out without the use of organic diluents or extra extraction agents and it can be applied as a sustainable hydrometallurgical method for removing transition metals from neodymium–iron–boron or samarium–cobalt permanentmagnets. The recycling of rare earths is of high importance because of the possible supply risk of these elements in the near future. The method was tested for the removal of cobalt and iron from samarium and neodymium, respectively. The highest distribution ratios for cobalt and iron were found with 8.5 and 9 M HCl. At the tested conditions, the concentrations of neodymium and samarium in the ionic liquidwere below 0.5 mg L−1 (0.5 ppm), even for feed concentrations of 45 g L−1. The separation factors of Nd/Fe and Sm/Co are 5.0 × 10^6 and 8.0 × 10^5, respectively. The percentage extraction of iron is still higher than 99.98% at loadings of the ionic liquids with 70 g L−1 of iron. The viscosity of the ionic liquid containing the tetrachloroferrate(III) complex [FeCl4]− is lower, and less depending on the feed concentration, than in the case with a tetrachlorocobaltate(II) anion [CoCl4]2−. After extraction, cobalt can be stripped very easily from the ionic liquid phase with water. However, due to the very high distribution ratio, iron could only be stripped by forming a water-soluble iron complex with ethylenediaminetetraacetic acid (EDTA). Also the possibility to extract chromium, nickel, aluminium, calcium and magnesium with trihexyl(tetradecyl)phosphonium chloride has been investigated, but the distribution ratios of theseelements are very low in the tested conditions.status: publishe

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom