Open Access
An interlaboratory comparison of techniques for extracting and analyzing trapped gases in ice cores
Author(s) -
Sowers Todd,
Brook Ed,
Etheridge David,
Blunier Thomas,
Fuchs Andreas,
Leuenberger Markus,
Chappellaz Jerome,
Barnola Jean Marc,
Wahlen Martin,
Deck Bruce,
Weyhenmeyer Connie
Publication year - 1997
Publication title -
journal of geophysical research: oceans
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.67
H-Index - 298
eISSN - 2156-2202
pISSN - 0148-0227
DOI - 10.1029/97jc00633
Subject(s) - ice core , standard deviation , calibration , environmental science , volume (thermodynamics) , analytical chemistry (journal) , atmospheric sciences , chemistry , climatology , geology , physics , environmental chemistry , statistics , thermodynamics , mathematics
We undertook an interlaboratory comparison of techniques used to extract and analyze trapped gases in ice cores. The intercomparison included analyses of standard reference gases and samples of ice from the Greenland Ice Sheet Project 2 (GISP2) site. Concentrations of CO 2 , CH 4 , the δ; 18 O of O 2 , the δ 15 N of N 2 , and the O 2 /N 2 , and Ar/N 2 ratios were measured in air standards and ice core samples. The standard reference scales for CO 2 and CH 4 were consistent at the ±2% level. The δ O 2 /N 2 and δ 18 O of O 2 measurements showed substantial deviations between the two laboratories able to measure these ratios. The deviations are probably related to errors associated with calibration of the working standards. The δ Ar N 2 and δ 15 N of N 2 measurements were consistent. Five laboratories analyzed the CH 4 concentration in a 4.2‐m section of the GISP2 ice core. The average of 20 discrete CH 4 measurements was 748±10 parts per billion by volume (ppbv). The standard deviation of these measurements was close to the total analytical uncertainty associated with the measurements. In all cases, those laboratories employing a dry extraction technique determined higher CH 4 values than laboratories using a wet extraction technique. The origin of this difference is unclear but may involve uncertainties associated with blank corrections. Analyses of the CO 2 concentration of trapped gases showed extreme variations which cannot be explained by analytical uncertainties alone. Three laboratories measured the [CO 2 ] on 21 discrete depths yielding an average value of 283±13 parts per million by volume (ppmv). In this case, the standard deviation was roughly a factor of 2 greater than the analytical uncertainties. We believe the variability in the measured [CO 2 ] results from impurities in the ice which may have compromised the [CO 2 ] of trapped gases in Greenland ice.