A Versatile Method to Enhance the Operational Current of Air-Stable Organic Gas Sensor for Monitoring of Breath Ammonia in Hemodialysis Patients
Author(s) -
Shang-Yu Yu,
Tin-Wei Tung,
Hongyu Yang,
GuanYu Chen,
CheChi Shih,
Y.-J. Lee,
Chang-Chiang Chen,
HsiaoWen Zan,
HsinFei Meng,
Chia-Jung Lu,
ChienLung Wang,
WenBin Jian,
Olivier Soppera
Publication year - 2019
Publication title -
acs sensors
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.055
H-Index - 57
ISSN - 2379-3694
DOI - 10.1021/acssensors.9b00223
Subject(s) - materials science , context (archaeology) , layer (electronics) , computer science , nanotechnology , paleontology , biology
Point-of-care (POC) application for monitoring of breath ammonia (BA) in hemodialysis (HD) patients has emerged as a promising noninvasive health monitoring approach. In this context, many organic gas sensors have been reported for BA detection. However, one of the major challenges for its integration with affordable household POC application is to achieve stable performance for accuracy and high operational current at low voltage for low-cost read-out circuitry. Herein, we exploited the stability of the Donor-Acceptor polymer on the cylindrical nanopore structure to realize the sensors with a high sensitivity and stability. Then, we proposed a double active layer (DL) strategy that exploits an ultrathin layer of Poly(3-hexylthiophene-2,5-diyl) (P3HT) to serve as a work function buffer to enhance the operational current. The DL sensor exhibits a sustainable enhanced operational current of microampere level and a stable sensing response even with the presence of P3HT layer. This effect is carefully examined with different aspects, including vertical composition profile of DL configuration, lifetime testing on different sensing layer, morphological analysis, and the versatility of the DL strategy. Finally, we utilize the DL sensor to conduct a tracing of BA concentration in two HD patients before and after HD, and correlate it with the blood urea nitrogen (BUN) levels. A good correlation coefficient of 0.96 is achieved. Moreover, the feasibility of DL sensor integrated into a low-cost circuitry was also verified. The results demonstrate the potential of this DL strategy to be used to integrate organic sensor for affordable household POC devices.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom