z-logo
open-access-imgOpen Access
Design and Analytical Performances of a Diclofenac Biosensor for Water Resources Monitoring
Author(s) -
Yacine Mazouzi,
Antoine Miche,
Alexis Loiseau,
Bruno Beito,
Christophe Méthivier,
Dietmar Knopp,
Michèle Salmain,
Souhir Boujday
Publication year - 2021
Publication title -
acs sensors
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.055
H-Index - 57
ISSN - 2379-3694
DOI - 10.1021/acssensors.1c01607
Subject(s) - quartz crystal microbalance , detection limit , biosensor , chromatography , analytical chemistry (journal) , chemistry , piezoelectricity , saturation (graph theory) , materials science , nanotechnology , adsorption , mathematics , organic chemistry , combinatorics , composite material
Because the broadly consumed pain killer diclofenac (DCF) is a recognized pollutant, monitoring of its concentration is routinely performed in surface waters. As a valuable alternative to chromatographic and immunochemical assays, we developed a piezoelectric immunosensor to quantify DCF, first in buffer (PBS) and then in river water samples. A sensing layer comprising DCF was built up on the surface of silica-coated quartz sensors using a robust coupling chemistry. Binding of a highly affine monoclonal anti-DCF antibody was monitored in real time by quartz crystal microbalance with dissipation (QCM-D) measurements from which were determined a dissociation constan K D of 0.24 nM and an acoustic antibody surface coverage of 1120 ng/cm 2 at saturation. On the other hand, an optical antibody surface coverage of 260 ng/cm 2 was determined by combined nanoplasmonic sensing measurement, giving a hydration percentage of 75% for the antibody monolayer. DCF assay was further set up following a competitive format for which binding of antibody to the sensing layer is inhibited by DCF in solution. The piezoelectric sensor response expressed as frequency shift Δ F was inversely related to the concentration of DCF with a dynamic range of 15-46 nM and a limit of detection (LoD) of 9.5 nM (2.8 μg/L) in PBS. This piezoelectric immunosensor was eventually applied to the assay of DCF in surface water samples taken at three different locations in the Seine and Marne rivers. The calculated concentration of DCF in these samples was in good agreement with official data published by the French center of water analysis eaufrance.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom