An Improved Reversed-Phase High-Performance Liquid Chromatography Method for the Analysis of Related Substances of Prednisolone in Active Ingredient
Author(s) -
Matjaž Finšgar,
Amra Perva-Uzunalić,
Heiko Behr,
Nina Ledinek,
Željko Knez,
Zoran Novak
Publication year - 2020
Publication title -
acs omega
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.779
H-Index - 40
ISSN - 2470-1343
DOI - 10.1021/acsomega.0c00037
Subject(s) - chromatography , prednisolone , high performance liquid chromatography , active ingredient , chemistry , acetonitrile , pharmacology , medicine , surgery
Prednisolone, an important active pharmaceutical ingredient, is a synthetic glucocorticoid used for the preparation of various pharmaceutical products with anti-inflammatory and immunosuppressive properties. It is a challenge in high-performance liquid chromatography (HPLC) to separate the prednisolone peak and its structurally related substance (hydrocortisone), which only differs in a double bond at the C-1 position. Successful application of the HPLC method according to the European Pharmacopoeia monograph for related substances of prednisolone is very often limited to the chromatographic system available. This is due to the nonbaseline separation of the prednisolone and hydrocortisone peaks, which is strongly influenced by the instrument parameters and the chosen C18 column. First, an adjusted European Pharmacopoeia method for related substances of prednisolone was developed within the allowable adjustments. Next, an improved stability-indicating reversed-phase HPLC method for related substances of prednisolone was developed and validated for use in quality control laboratories for routine analysis. The optimized separation was performed on a Phenomenex Gemini C18 column (150 mm × 4.6 mm, 3 μm) using a gradient mobile-phase system consisting of acetonitrile/tetrahydrofuran/water (15:10:75 v/v/v), acetonitrile/water (80:20 v/v), and ultraviolet detection at 254 nm. A baseline separation was achieved, and stability indicating capability was demonstrated by a forced degradation study. A full validation procedure was performed in accordance with International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use guidelines.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom