Core–Shell–Shell Nanoparticles for NIR Fluorescence Imaging and NRET Swelling Reporting of Injectable or Implantable Gels
Author(s) -
Hannah R. Shanks,
Amir H. Milani,
Dongdong Lu,
Brian R. Saunders,
Louise Carney,
Daman J. Adlam,
Judith A. Hoyland,
Christopher Blount,
Mark Dickinson
Publication year - 2019
Publication title -
biomacromolecules
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.689
H-Index - 220
eISSN - 1526-4602
pISSN - 1525-7797
DOI - 10.1021/acs.biomac.9b00463
Subject(s) - swelling , fluorescence , fluorescence lifetime imaging microscopy , nanoparticle , self healing hydrogels , materials science , acrylic acid , biomedical engineering , chemical engineering , chemistry , nanotechnology , composite material , polymer chemistry , polymer , medicine , physics , monomer , quantum mechanics , engineering
Injectable gels that support load are desirable for restoring the mechanical properties of degenerated load-bearing tissue. As these gels become increasingly sophisticated, the need to remotely image them and monitor their swelling increases. However, imaging such gels and monitoring their swelling using non-invasive means is challenging. Here, we use a very low concentration of near infrared (NIR) core-shell-shell (CSS) reporter nanoparticles to both image and monitor swelling changes of two load-supporting gels. The load-supporting injectable gel consisted of covalently interlinked pH-responsive microgel (MG) particles. The latter gel was not cytotoxic and is termed a doubly crosslinked microgel (DX MG). Inclusion of a complementary fluorescent dye enabled ratiometric monitoring of gel swelling changes in response to pH via nonradiative resonance energy transfer (NRET). In addition, changes in the CSS nanoparticle emission intensity provided a NIR-only method that could also be used to monitor gel swelling. The gel was able to be imaged using NIR light, after being subcutaneously injected into a tissue model. To demonstrate versatility of our approach, CSS and the dye were included within a model implantable gel (poly(acrylamide/acrylic acid)) and fluorescent detection of swelling investigated. Because the concentrations of the reporting species were too low to affect the mechanical properties, our approach to remote gel imaging and swelling monitoring has good potential for application in injectable gels and implants.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom